OSHA SearchOSHA records by employer

Green Construction Company Incorporated: OSHA inspections and violations

London, Kentucky · Commercial and Institutional Building Construction · NAICS 236220

5inspections
6citation items
$3,675current penalties
Feb 17, 2016last inspection

OSHA has inspected Green Construction Company Incorporated 5 times in Kentucky since 1985.

The latest one began on Feb 17, 2016 on a referral, in Laurel Fork.

Those inspections ended with 6 citation items: 3 serious and 3 other-than-serious.

Penalties were first proposed at $3,675 and still stand at $3,675.

[Reserved] comes up most often in these citations: 2 items under 1926.550.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Green Construction Company Incorporated averages $3,500 (1 cited inspection).

Green Construction Company Incorporated: OSHA citation items per year, 1985 to 2016
Citation items per year, by inspection date.

Kentucky · latest 90 days of OSHA records

190employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Kentucky

Checking a subcontractor, a client or your own company? Watch Green Construction Company Incorporated and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341289767 OPENED FEB 17, 2016Closed

Referral · Partial · Safety · 20 employees at the site · Closed Apr 24, 2017

Henderson Settlement 16773 State Hwy 190, Laurel Fork, KY 40940 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,500$3,500Jun 13, 2016Final

Inspection 313579641 OPENED NOV 9, 2009Closed

Unprogrammed related · Partial · Safety · 4 employees at the site · Closed Nov 24, 2009

Rt 1 Box 88, Pineville, KY 40977 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308083120 OPENED NOV 8, 2004Closed

Planned · Complete · Safety · 5 employees at the site · Closed Nov 8, 2004

310 College St - Union College, Barbourville, KY 40906 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 115954349 OPENED OCT 7, 1992Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jan 4, 1993

Fine Arts Bldg., Uk Extension College, Cumberland, KY 40823 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$175$175Nov 20, 1992Closed
Citation 1, item 1b
29 CFR 1926.1052(b)(1) · Stairways in construction
Serious$0$0Nov 20, 1992Closed

Inspection 18600684 OPENED NOV 14, 1985Closed

Planned · Complete · Safety · 14 employees at the site · Closed Jan 27, 1986

East 9th St., London, KY 40741 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.550(b)(2) · [Reserved]
Other-than-serious$0$0Jan 14, 1986Closed
Citation 1, item 2
29 CFR 1926.550(b)(2) · [Reserved]
Other-than-serious$0$0Jan 14, 1986Closed
Citation 1, item 3
29 CFR 1926.602(a)(9)(i) · Earthmovers and forklifts in construction
Other-than-serious$0$0Jan 14, 1986Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(b)(1)

(1) Except during stairway construction, foot traffic is prohibited on stairways with pan stairs where the treads and/or landings are to be filled in with concrete or other material at a later date, unless the stairs are temporarily fitted with wood or other solid material at least to the top edge of each pan. Such temporary treads and landings shall be replaced when worn below the level of the top edge of the pan.

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

29 CFR 1926.550 · [Reserved]

29 CFR 1926.602 · Earthmovers and forklifts in construction

Other commercial and institutional building construction employers in Kentucky

Alert subscribers get notified of each newly cited employer in Kentucky the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.