OSHA SearchOSHA records by employer

Greentree Solid Waste Authority: OSHA inspections and violations

Ruidoso Downs, New Mexico · Solid Waste Landfill · NAICS 562212

2inspections
20citation items
$6,075current penalties
Jul 6, 2017last inspection

OSHA has inspected Greentree Solid Waste Authority 2 times in New Mexico since 2010.

The latest one began on Jul 6, 2017 as a planned inspection, in Ruidoso.

Those inspections ended with 20 citation items: 8 serious and 12 other-than-serious.

Penalties were first proposed at $6,075 and still stand at $6,075.

Permit-required confined spaces comes up most often in these citations: 4 items under 1910.146.

How that compares: the median penalty per cited inspection for staffing, cleaning and waste services employers since 2015 is $2,201, and Greentree Solid Waste Authority averages $5,850 (1 cited inspection).

Greentree Solid Waste Authority: OSHA citation items per year, 2010 to 2017
Citation items per year, by inspection date.

New Mexico · latest 90 days of OSHA records

35employers cited

Get notified the morning OSHA posts each new citation in New Mexico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Mexico

Checking a subcontractor, a client or your own company? Watch Greentree Solid Waste Authority and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342450798 OPENED JUL 6, 2017Closed

Planned · Complete · Safety · Local government · 18 employees at the site · Closed Feb 6, 2018

26590 Us Highway 70, Ruidoso, NM 88345 · Other Nonhazardous Waste Treatment and Disposal · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$1,500$1,500Jan 5, 2018Final
Citation 1, item 2
29 CFR 1910.106(d)(5)(iii) · Flammable liquids
Serious$600$600Jan 5, 2018Final
Citation 1, item 3
29 CFR 1910.106(e)(9)(iii) · Flammable liquids
Serious$600$600Jan 5, 2018Final
Citation 1, item 4
29 CFR 1910.110(b)(6)(i) · Storage and handling of liquefied petroleum gases
Serious$750$750Jan 5, 2018Final
Citation 1, item 5
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,050$1,050Jan 5, 2018Final
Citation 1, item 6
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$600$600Jan 5, 2018Final
Citation 1, item 7
29 CFR 1910.253(b)(1)(ii) · Gas welding and cutting
Serious$750$750Jan 5, 2018Final
Citation 2, item 1
29 CFR 1910.23(b)(9) · Ladders in general industry
Other-than-serious$0$0Jan 5, 2018Final
Citation 2, item 2
29 CFR 1910.23(b)(10) · Ladders in general industry
Other-than-serious$0$0Jan 5, 2018Final
Citation 2, item 3
29 CFR 1910.146(d)(3) · Permit-required confined spaces
Other-than-serious$0$0Jan 5, 2018Final
Citation 2, item 4
29 CFR 1910.146(f)(5) · Permit-required confined spaces
Other-than-serious$0$0Jan 5, 2018Final
Citation 2, item 5
29 CFR 1910.146(f)(7) · Permit-required confined spaces
Other-than-serious$0$0Jan 5, 2018Final
Citation 2, item 6
29 CFR 1910.146(f)(12) · Permit-required confined spaces
Other-than-serious$0$0Jan 5, 2018Final
Citation 2, item 7
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Jan 5, 2018Final
Citation 2, item 8
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Jan 5, 2018Final
Citation 2, item 9
29 CFR 1910.303(e) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 5, 2018Final
Citation 2, item 10
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 5, 2018Final

Inspection 314271107 OPENED APR 12, 2010Closed

Referral · Complete · Safety · Local government · 23 employees at the site · Closed Jun 28, 2010

222 2nd Street, Ruidoso Downs, NM 88346 · Solid Waste Landfill · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$225$225Jun 9, 2010Closed
Citation 2, item 1
29 CFR 1910.305(g)(1)(iva) · Electrical wiring methods
Other-than-serious$0$0Jun 9, 2010Closed
Citation 2, item 2
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Jun 9, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(5)(iii)

(iii) Office occupancies. Storage shall be prohibited except that which is required for maintenance and operation of building and operation of equipment. Such storage shall be kept in closed metal containers stored in a storage cabinet or in safety cans or in an inside storage room not having a door that opens into that portion of the building used by the public.

29 CFR 1910.106(e)(9)(iii)

(iii) Waste and residue. Combustible waste material and residues in a building or unit operating area shall be kept to a minimum, stored in covered metal receptacles and disposed of daily.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(b)(6)(i)

(6) Location of containers and regulating equipment. (i) Containers, and first stage regulating equipment if used, shall be located outside of buildings, except under one or more of the following:

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Ladders in general industry

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other solid waste landfill employers in New Mexico

Alert subscribers get notified of each newly cited employer in New Mexico the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.