Inspection 346826209 OPENED JUN 28, 2023Closed
Rt 38 And 1st Street, Dekalb, IL 60115 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Greg Stephens 4 times in Illinois since 1997.
The latest one began on Jun 28, 2023 after a complaint, in Dekalb.
Those inspections ended with 3 citation items: 3 serious.
Penalties were first proposed at $2,347 and still stand at $2,347.
Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,078, and Greg Stephens averages $1,847 (1 cited inspection).
Want to know if OSHA cites Greg Stephens again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this companyRt 38 And 1st Street, Dekalb, IL 60115 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
460 East Lincoln Highway, Dekalb, IL 60115 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $1,847 | $1,847 | May 24, 2017 | Final |
| Citation 1, item 1b 29 CFR 1926.451(f)(3) · Scaffolds, general requirements |
Serious | $0 | $0 | May 24, 2017 | Final |
Rt. 23 & Dresser Rd., De Kalb, IL 60115 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
821 East Lincoln Hwy, De Kalb, IL 60115 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.706(b) · Requirements for masonry construction |
Serious | $500 | $500 | Sep 22, 1997 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(e)(1)
(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.
29 CFR 1926.451(f)(3)
(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.
29 CFR 1926.706(b)
(b) All masonry walls over eight feet in height shall be adequately braced to prevent overturning and to prevent collapse unless the wall is adequately supported so that it will not overturn or collapse. The bracing shall remain in place until permanent supporting elements of the structure are in place.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.