OSHA SearchOSHA records by employer

Growgeneration California Corp: OSHA inspections and violations

Tigard, Oregon · Nursery, Garden Center, and Farm Supply Stores · NAICS 444220

2inspections
7citation items
$275current penalties
Apr 8, 2021last inspection

Since 2021, OSHA inspectors have visited Growgeneration California Corp in Oregon 2 times.

The most recent inspection opened on Apr 8, 2021 to follow up on an earlier case, in Tigard.

In all, OSHA issued 7 citation items: 2 serious and 5 other-than-serious.

The penalties, $275 in total, stand where OSHA first set them.

The rule cited most here is 1910.305 (electrical wiring methods), 3 times.

Among retail employers, the typical cited inspection since 2015 ends with a $1,750 penalty. Growgeneration California Corp averages $275 across 1 cited inspection.

Growgeneration California Corp: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

391employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Growgeneration California Corp and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Growgeneration California Corp at 2 sites in 2 states. Together they've had 3 inspections and $775 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 2 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 345246417 OPENED APR 8, 2021Closed

Follow-up · Partial · Safety · 8 employees at the site · Closed Apr 8, 2021

11564 Sw Pacific Hwy, Tigard, OR 97223 · Nursery, Garden Center, and Farm Supply Stores · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345159206 OPENED FEB 3, 2021Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Jul 1, 2021

11564 Sw Pacific Hwy, Tigard, OR 97223 · Nursery, Garden Center, and Farm Supply Stores · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-002-2101(2)
Serious$175$175Feb 25, 2021Final
Citation 1, item 2
29 CFR OAR 437-002-0041(5)(A)
Serious$100$100Feb 25, 2021Final
Citation 2, item 3
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$0$0Feb 25, 2021Final
Citation 2, item 4
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Feb 25, 2021Final
Citation 2, item 5
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$0$0Feb 25, 2021Final
Citation 2, item 6
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Other-than-serious$0$0Feb 25, 2021Final
Citation 2, item 7
29 CFR OAR 437-001-0765(1)-3
Other-than-serious$0$0Feb 25, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(7)(iv)

(iv) There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(1)(ii)

(ii) Unused openings in cabinets, boxes, and fittings shall be effectively closed.

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

Other nursery, garden center, and farm supply stores employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.