OSHA SearchOSHA records by employer

GSF Builders, Inc: OSHA inspections and violations

Amarillo, Texas · Residential Remodelers · NAICS 236118

1inspections
5citation items
$7,000current penalties
Jun 9, 2016last inspection

OSHA has inspected GSF Builders, Inc once in Texas.

The inspection began on Jun 9, 2016 after a complaint, in Amarillo.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $7,000 and still stand at $7,000.

Trench protection comes up most often in these citations: 2 items under 1926.652.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and GSF Builders, Inc averages $7,000 (1 cited inspection).

GSF Builders, Inc: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites GSF Builders, Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341547115 OPENED JUN 9, 2016Closed

Complaint · Partial · Safety · 35 employees at the site · Closed Jan 30, 2019

6010 W. Amarillo Blvd., Amarillo, TX 79106 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$2,100$2,100Jul 29, 2016Final
Citation 1, item 2a
29 CFR 1926.651(a) · Excavations
Serious$4,900$4,900Jul 29, 2016Final
Citation 1, item 2b
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0Jul 29, 2016Final
Citation 1, item 2c
29 CFR 1926.652(a)(1)(i) · Trench protection
Serious$0$0Jul 29, 2016Final
Citation 1, item 2d
29 CFR 1926.652(b)(1) · Trench protection
Serious$0$0Jul 29, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(a)

(a) Surface encumbrances. All surface encumbrances that are located so as to create a hazard to employees shall be removed or supported, as necessary, to safeguard employees.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

Other residential remodelers employers in Texas