OSHA SearchOSHA records by employer

Guch Sheet Metal and AC Inc: OSHA inspections and violations

Stuart, Florida · Sheet Metal Work Manufacturing · NAICS 332322

1inspections
4citation items
$3,840current penalties
Apr 14, 2015last inspection

OSHA has inspected Guch Sheet Metal and AC Inc once in Florida.

The inspection began on Apr 14, 2015 as part of a related case, in Stuart.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $6,400 and now stand at $3,840, 40% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 2 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Guch Sheet Metal and AC Inc averages $3,840 (1 cited inspection).

Guch Sheet Metal and AC Inc: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

311employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Guch Sheet Metal and AC Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340561661 OPENED APR 14, 2015Closed

Unprogrammed related · Partial · Safety · 5 employees at the site · Closed Nov 9, 2016

3041 Se Dominica Terrace Viesel Fuel, Llc, Stuart, FL 34997 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.243(c)(1) · Guarding of portable powered tools
Serious$1,600$960Jun 24, 2015Final
Citation 1, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$1,600$960Jun 24, 2015Final
Citation 1, item 3
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Serious$1,600$960Jun 24, 2015Final
Citation 1, item 4
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$1,600$960Jun 24, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.243(c)(1)

(c) Portable abrasive wheels—(1) General requirements. Abrasive wheels shall be used only on machine provided with safety guards as defined in paragraph (c) (1) through (4) of this section.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(1)(i)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. (i) Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed.

Other sheet metal work manufacturing employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.