OSHA SearchOSHA records by employer

Guinco Enterprises Corp.: OSHA inspections and violations

Dallas, Texas · Appliance Repair and Maintenance · NAICS 811412

1inspections
3citation items
$14,850current penalties
Sep 14, 2016last inspection

OSHA inspectors have visited Guinco Enterprises Corp. in Texas one time.

It opened on Sep 14, 2016 after a fatality or catastrophe, in Dallas.

In all, OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

The proposed penalties came to $21,246; today they stand at $14,850, 30% less.

Among repair and personal services employers, the typical cited inspection since 2015 ends with a $1,200 penalty. Guinco Enterprises Corp. averages $14,850 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Guinco Enterprises Corp.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Guinco Enterprises Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341772705 OPENED SEP 14, 2016Closed

Fatality or catastrophe · Complete · Safety · 65 employees at the site · Closed Jan 17, 2018

2727 Shelby Avenue Unit I, Dallas, TX 75219 · Appliance Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Incident on Sep 13, 2016 (fatal): Employee is electrocuted while performing repairs in a dryer

At approximately 2:00 p.m. on September 13, 2016, an employee was performing repairs on a stackable dryer unit and he was electrocuted.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.333(a)(2) · Working near live electrical parts
Serious$8,873$6,200Feb 24, 2017Final
Citation 1, item 2
29 CFR 1910.335(a)(2)(i) · Safeguards for personnel protection
Serious$8,873$6,200Feb 24, 2017Final
Citation 2, item 1
29 CFR 1904.39(a) · Reporting deaths and severe injuries
Other-than-serious$3,500$2,450Feb 24, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.39 · Reporting deaths and severe injuries

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(a)(2)

(2) Energized parts. If the exposed live parts are not deenergized (i.e., for reasons of increased or additional hazards or infeasibility), other safety-related work practices shall be used to protect employees who may be exposed to the electrical hazards involved. Such work practices shall protect employees against contact with energized circuit parts directly with any part of their body or indirectly through some other conductive object. The work practices that are used shall be suitable for the conditions under which the work is to be performed and for the voltage level of the exposed electric conductors or circuit parts. Specific work practice requirements are detailed in paragraph (c) of this section.

29 CFR 1910.335 · Safeguards for personnel protection

29 CFR 1910.335(a)(2)(i)

(2) General protective equipment and tools. (i) When working near exposed energized conductors or circuit parts, each employee shall use insulated tools or handling equipment if the tools or handling equipment might make contact with such conductors or parts. If the insulating capability of insulated tools or handling equipment is subject to damage, the insulating material shall be protected.

Other appliance repair and maintenance employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.