OSHA SearchOSHA records by employer

Gulf Coast Welding Contractors LLC: OSHA inspections and violations

Houston, Texas · Employment Placement Agencies · NAICS 561311

1inspections
7citation items
$25,895current penalties
Jul 19, 2023last inspection

OSHA inspectors have visited Gulf Coast Welding Contractors LLC in Texas one time.

It opened on Jul 19, 2023 after a fatality or catastrophe, in Houston.

In all, OSHA issued 7 citation items: 6 serious and 1 other-than-serious.

The penalties, $25,895 in total, stand where OSHA first set them.

The rule cited most here is 1910.305 (electrical wiring methods), 2 times.

Among staffing, cleaning and waste services employers, the typical cited inspection since 2015 ends with a $2,217 penalty. Gulf Coast Welding Contractors LLC averages $25,895 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Gulf Coast Welding Contractors LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Gulf Coast Welding Contractors LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346849607 OPENED JUL 19, 2023Closed

Fatality or catastrophe · Partial · Safety · 12 employees at the site · Closed Dec 27, 2023

11011 Sheldon Rd. Induction Line, Houston, TX 77044 · Employment Placement Agencies · OSHA's record · Phone and website on Google Maps

Incident on Jul 19, 2023 (fatal): Employee is electrocuted when tubing strikes induction coil

At 7:30 am on July 19, 2023, an employee was working on a steel tubing induction line and he was receiving tubing on the conveyor. The employee was waiting for tubing to be fed by the kicker which kicked the tubing in place but it was misaligned. The employee was trying to align the tubing when the backup caused tubing to be lifted up against the induction coils. The contact with the coils caused current to be transmitted through the tubing and the employee was electrocuted.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(5) · Machine guarding
Serious$4,465$4,465Nov 16, 2023Final
Citation 1, item 2
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$4,465$4,465Nov 16, 2023Final
Citation 1, item 3a
29 CFR 1910.305(g)(1)(iv)(c) · Electrical wiring methods
Serious$4,465$4,465Nov 16, 2023Final
Citation 1, item 3b
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Nov 16, 2023Final
Citation 1, item 4
29 CFR 1910.333(c)(6) · Working near live electrical parts
Serious$6,250$6,250Nov 16, 2023Final
Citation 1, item 5
29 CFR 1910.335(a)(1)(i) · Safeguards for personnel protection
Serious$6,250$6,250Nov 16, 2023Final
Citation 2, item 1
29 CFR 1910.137(c)(2)(viii) · Electrical protective equipment
Other-than-serious$0$0Nov 16, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.137 · Electrical protective equipment

29 CFR 1910.137(c)(2)(viii)

(viii) Electrical protective equipment shall be subjected to periodic electrical tests. Test voltages and the maximum intervals between tests shall be in accordance with Table I-4 and Table I-5.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(5)

(5) Exposure of blades. When the periphery of the blades of a fan is less than seven (7) feet above the floor or working level, the blades shall be guarded. The guard shall have openings no larger than one-half ( 1/2) inch.

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.304(g)(5)

(5) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.335 · Safeguards for personnel protection

Other employment placement agencies employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.