2inspections
6citation items
$3,255current penalties
Jan 6, 2015last inspection

Gulfside Roofing, Inc. has 2 OSHA inspections on record in Florida, the first in 2002.

OSHA's last visit started on Jan 6, 2015 as a planned inspection, in Holmes Beach.

Across those inspections OSHA issued 6 citation items: 6 serious.

OSHA proposed $5,175 in penalties. After settlements and reviews the total is $3,255, down 37%.

Most often, OSHA cited 1926.501, fall protection in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Gulfside Roofing, Inc. averages $2,880 over 1 cited inspection in that time.

Gulfside Roofing, Inc.: OSHA citation items per year, 2002 to 2015
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

70 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Gulfside Roofing, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340186204 OPENED JAN 6, 2015Closed

Planned · Partial · Safety · 20 employees at the site · Closed Apr 15, 2016

4408 Gulf Drive, Holmes Beach, FL 34217 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,000$1,200Feb 3, 2015Final
Citation 1, item 2a
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$2,800$1,680Feb 3, 2015Final
Citation 1, item 2b
29 CFR 1926.403(b)(1)(iii) · Electrical equipment on job sites
Serious$0$0Feb 3, 2015Final
Citation 1, item 2c
29 CFR 1926.405(a)(2)(ii)(i) · Job-site wiring
Serious$0$0Feb 3, 2015Final
Citation 1, item 2d
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$0$0Feb 3, 2015Final

Inspection 305643355 OPENED AUG 19, 2002Closed

Unprogrammed other · Complete · Safety · 6 employees at the site · Closed Sep 17, 2002

1303 17th St, West, Palmetto, FL 34221 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$375$375Sep 11, 2002Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(1)(iii)

(iii) Electrical insulation.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(i)

(iii) Guarding. For temporary wiring over 600 volts, nominal, fencing, barriers, or other effective means shall be provided to prevent access of other than authorized and qualified personnel.

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.