Inspection 344909510 OPENED SEP 2, 2020Closed
5655 N Peterson Rd, Sedalia, CO 80135 · Medicinal and Botanical Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Aug 27, 2020: Employee is burned when spilled heptane vapor ignites
At 2:30 p.m. on August 27, 2020, an employee was testing a new membrane filter machine with fresh heptane solvent. The heptane solvent leaked from a valve, and the employee caught it with a plastic pan and poured it into a bucket. Vapor from the heptane solvent ignited due to a nearby heat gun the employee had left turned on. The employee suffered burns to the hand, forearm and neck. The employee was hospitalized.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.106(e)(2)(iv)(c) · Flammable liquids |
Serious | $0 | $0 | Oct 9, 2020 | Final |
| Citation 1, item 2 29 CFR 1910.106(e)(6)(i) · Flammable liquids |
Serious | $0 | $0 | Oct 9, 2020 | Final |