OSHA SearchOSHA records by employer

H B Carbide Company: OSHA inspections and violations

Lewiston, Michigan · Cutting Tool and Machine Tool Accessory Manufacturing · NAICS 333515

6inspections
22citation items
$4,885current penalties
Jan 12, 2016last inspection

Since 2002, OSHA inspectors have visited H B Carbide Company in Michigan 6 times.

The most recent inspection opened on Jan 12, 2016 on a referral, in Lewiston.

In all, OSHA issued 22 citation items: 8 serious and 14 other-than-serious.

The proposed penalties came to $9,750; today they stand at $4,885, 50% less.

The rule cited most here is 1910.305 (electrical wiring methods), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. H B Carbide Company averages $3,500 across 1 cited inspection.

H B Carbide Company also files yearly injury logs with OSHA, summarized below.

H B Carbide Company: OSHA citation items per year, 2002 to 2016
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

641employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch H B Carbide Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341155794 OPENED JAN 12, 2016Closed

Referral · Partial · Health · 125 employees at the site · Closed May 16, 2016

4210 Doyle, Lewiston, MI 49756 · Cutting Tool and Machine Tool Accessory Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 325.51103(A)(III)
Serious$3,500$1,750Apr 5, 2016Final
Citation 1, item 1b
29 CFR 325.51105
Serious$0$0Apr 5, 2016Final
Citation 1, item 2a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$3,500$1,750Apr 5, 2016Final
Citation 1, item 2b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Apr 5, 2016Final
Citation 1, item 2c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Apr 5, 2016Final

Inspection 312030869 OPENED JUL 17, 2014Closed

Planned · Complete · Safety · 130 employees at the site · Closed Nov 10, 2014

4210 Doyle Dr, Lewiston, MI 49756 · Metalworking Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,400$560Oct 8, 2014Closed
Citation 1, item 2
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Serious$1,050$525Oct 8, 2014Closed
Citation 2, item 1 Other-than-serious$0$0Oct 8, 2014Closed
Citation 2, item 2 Other-than-serious$0$0Oct 8, 2014Closed
Citation 2, item 3 Other-than-serious$0$0Oct 8, 2014Closed
Citation 2, item 4a
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 8, 2014Closed
Citation 2, item 4b
29 CFR 1910.305(a)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Oct 8, 2014Closed
Citation 2, item 4c
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Oct 8, 2014Closed

Inspection 312070360 OPENED APR 24, 2012Closed

Complaint · Partial · Health · 120 employees at the site · Closed May 25, 2012

4210 Doyle Dr, Lewiston, MI 49756 · Metalworking Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308880780 OPENED MAY 8, 2008Closed

Referral · Partial · Health · 111 employees at the site · Closed Jun 24, 2008

4210 Doyle Dr, Lewiston, MI 49756 · Cutting Tool and Machine Tool Accessory Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307713412 OPENED MAR 21, 2006Closed

Planned · No inspection · Safety · Closed May 3, 2006

23461 Industrial Park Dr, Farmington Hills, MI 48335 · Cutting Tool and Machine Tool Accessory Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 304884380 OPENED OCT 9, 2002Closed

Planned · Complete · Safety · 100 employees at the site · Closed Jan 7, 2003

4210 Doyle Dr, Lewiston, MI 49756 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$300$300Nov 21, 2002Closed
Citation 2, item 1 Other-than-serious$0$0Nov 21, 2002Closed
Citation 2, item 2 Other-than-serious$0$0Nov 21, 2002Closed
Citation 2, item 3 Other-than-serious$0$0Nov 21, 2002Closed
Citation 2, item 4 Other-than-serious$0$0Nov 21, 2002Closed
Citation 2, item 5a
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Other-than-serious$0$0Nov 21, 2002Closed
Citation 2, item 5b
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Nov 21, 2002Closed
Citation 2, item 5c
29 CFR 1910.305(g)(2) · Electrical wiring methods
Other-than-serious$0$0Nov 21, 2002Closed
Citation 2, item 6
29 CFR 1910.169(b)(3)(iv) · Air receivers
Other-than-serious$0$0Nov 21, 2002Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Lewiston site logged 8 recordable injuries or illnesses among about 144 workers: 5.4 per 100 full-time workers, against a median of 2.3 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
H.B. Carbide
Lewiston · 2023
144 805.42.3

Included with any plan: 3 more yearly logs from these sites, back to 2020, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.134(f)(2)

(2) Deep breathing. In a normal standing position, the subject shall breathe slowly and deeply, taking caution so as not to hyperventilate.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.169 · Air receivers

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 4081.1222

29 CFR 4081.1223

29 CFR 4081.15

29 CFR 4081.2015

29 CFR 4081.221

29 CFR 4081.36

29 CFR 4081.3845

29 CFR 4081.4005

29 CFR 4081.727

Other cutting tool and machine tool accessory manufacturing employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.