OSHA SearchOSHA records by employer

H.B. Fuller Company: OSHA inspections and violations

Walker, Michigan · Adhesive Manufacturing · NAICS 325520

10inspections
17citation items
$13,340current penalties
May 15, 2025last inspection

OSHA has inspected H.B. Fuller Company 10 times in Michigan since 1993.

The latest one began on May 15, 2025 after a complaint, in Clawson.

Those inspections ended with 17 citation items: 13 serious and 4 other-than-serious.

Penalties were first proposed at $22,150 and now stand at $13,340, 40% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 5 items under 1910.147.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and H.B. Fuller Company averages $2,367 (3 cited inspections).

1 inspection on this page followed a fatal incident.

H.B. Fuller Company also files yearly injury logs with OSHA, summarized below.

H.B. Fuller Company: OSHA citation items per year, 1993 to 2025
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

643employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch H.B. Fuller Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show H.B. Fuller Company at 20 sites in 7 states. Together they've had 66 inspections and $325,963 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 20 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 348251133 OPENED MAY 15, 2025Closed

Complaint · Partial · Health · 70 employees at the site · Closed Sep 9, 2025

1000 N Crooks, Clawson, MI 48017 · Bolt, Nut, Screw, Rivet, and Washer Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340055797 OPENED AUG 3, 2016Closed

Complaint · Partial · Safety · 84 employees at the site · Closed Mar 14, 2017

2727 Kinney Ave Nw, Walker, MI 49534 · Adhesive Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$4,800$2,400Oct 5, 2016Final

Inspection 340039726 OPENED JUN 2, 2016Closed

Complaint · Partial · Health · 65 employees at the site · Closed Jul 25, 2016

2727 Kinney Ave Sw, Walker, MI 49534 · Adhesive Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341404879 OPENED APR 25, 2016Closed

Complaint · Partial · Safety · 65 employees at the site · Closed Oct 31, 2016

2727 Kinney Ave Sw, Walker, MI 49534 · Adhesive Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Serious$2,450$2,450May 27, 2016Final
Citation 1, item 1b
29 CFR 1910.147(c)(5)(ii) · Lockout/tagout
Serious$0$0May 27, 2016Final
Citation 1, item 1c
29 CFR 1910.147(e)(3) · Lockout/tagout
Serious$0$0May 27, 2016Final
Citation 1, item 1d Serious$0$0May 27, 2016Final

Inspection 341404887 OPENED APR 25, 2016Closed

Complaint · Partial · Health · 65 employees at the site · Closed Aug 4, 2017

2727 Kinney Ave Sw, Walker, MI 49534 · Adhesive Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 325.52130(4)
Serious$4,500$2,250Jun 23, 2016Final
Citation 1, item 1b
29 CFR 325.52131(5)
Serious$0$0Jun 23, 2016Final
Citation 1, item 1c
29 CFR 325.52133(1)
Serious$0$0Jun 23, 2016Final
Citation 1, item 1d
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Jun 23, 2016Final
Citation 1, item 1e
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Jun 23, 2016Final

Inspection 316163286 OPENED JUN 13, 2013Closed

Unprogrammed other · Partial · Health · 40 employees at the site · Closed Jul 9, 2013

2727 Kinney Ave Nw, Walker, MI 49534 · Adhesive Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315392886 OPENED NOV 29, 2012Closed

Complaint · Partial · Safety · 43 employees at the site · Closed Mar 19, 2013

2727 Kinney Nw, Grand Rapids, MI 49504 · Adhesive Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$1,750$700Jan 3, 2013Closed
Citation 1, item 2a Serious$1,750$700Jan 3, 2013Closed
Citation 1, item 2b Other-than-serious$0$0Jan 3, 2013Closed
Citation 2, item 1
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Jan 3, 2013Closed

Inspection 307733733 OPENED DEC 14, 2005Closed

Accident · Partial · Health · 45 employees at the site · Closed Aug 27, 2008

2727 Kinney Nw, Grand Rapids, MI 49504 · Adhesive Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Dec 16, 2005 (fatal): Employee is overcome by chemical vapors and dies

On December 12, 2005, Employee #1 was working on the third shift for a chemical manufacturer. He was performing tasks in a mixing room where various adhesives w ere being manufactured. Some of the adhesives, for example, MDI (methylene diphe nyl diisocyanate), contained diisocyanates. Employee #1 was overcome when he inh aled fumes, and he was killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$4,200$2,940May 26, 2006Final
Citation 2, item 1 Other-than-serious$450$325May 26, 2006Final
2 older inspections

Inspection 308848803 OPENED DEC 14, 2005Closed

Unprogrammed related · Partial · Health · 45 employees at the site · Closed Aug 27, 2008

2727 Kinney Nw, Grand Rapids, MI 49504 · Adhesive Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$2,250$1,575May 26, 2006Final

Inspection 114879034 OPENED JAN 5, 1993Closed

Accident · Partial · Safety · 45 employees at the site · Closed Jul 2, 1993

2727 Kinney Nw, Grand Rapids, MI 49504 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Clawson site logged 1 recordable injury or illness among about 79 workers: 1.4 per 100 full-time workers, against a median of 3.2 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
HB Fuller Company
Clawson · 2025
79 101.43.2

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.147 · Lockout/tagout

29 CFR 3254.7201

29 CFR 4080.1011

29 CFR 4081.3309

29 CFR 4081.3392

29 CFR 4082.2129

Other adhesive manufacturing employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.