OSHA SearchOSHA records by employer

H Robare Construction Inc: OSHA inspections and violations

Burlington, Vermont · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

1inspections
5citation items
$3,000current penalties
Aug 17, 2016last inspection

OSHA has inspected H Robare Construction Inc once in Vermont.

The inspection began on Aug 17, 2016 on a referral, in Burlington.

That inspection ended with 5 citation items: 3 serious and 2 other-than-serious.

Penalties were first proposed at $8,400 and now stand at $3,000, 64% lower after settlements or reviews.

Job-site wiring comes up most often in these citations: 2 items under 1926.405.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and H Robare Construction Inc averages $3,000 (1 cited inspection).

H Robare Construction Inc: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Vermont · latest 90 days of OSHA records

25employers cited

Get notified the morning OSHA posts each new citation in Vermont: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Vermont

Checking a subcontractor, a client or your own company? Watch H Robare Construction Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341728855 OPENED AUG 17, 2016Closed

Referral · Partial · Safety · 5 employees at the site · Closed Jan 6, 2017

191 College St., Burlington, VT 05401 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.304(i)(1) · Woodworking tools
Serious$1,600$900Dec 6, 2016Final
Citation 1, item 2a
29 CFR 1926.405(a)(2)(ii)(e) · Job-site wiring
Other-than-serious$2,800$0Dec 6, 2016Final
Citation 1, item 2b
29 CFR 1926.405(a)(2)(ii)(f) · Job-site wiring
Other-than-serious$0$0Dec 6, 2016Final
Citation 1, item 3
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Serious$1,600$900Dec 6, 2016Final
Citation 1, item 4
29 CFR 1926.26 · Illumination
Serious$2,400$1,200Dec 6, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(i)

(i) At least one handrail; and

29 CFR 1926.26 · Illumination

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(i)(1)

(i) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(e)

(E) All lamps for general illumination shall be protected from accidental contact or breakage. Metal-case sockets shall be grounded.

Other new multifamily housing construction (except for-sale builders) employers in Vermont

Alert subscribers get notified of each newly cited employer in Vermont the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.