OSHA SearchOSHA records by employer

Haemonetics Corp: OSHA inspections and violations

Draper, Utah · Surgical Appliance and Supplies Manufacturing · NAICS 339113

7inspections
2citation items
$1,150current penalties
Mar 3, 2021last inspection

Haemonetics Corp has 7 OSHA inspections on record in Utah, the first in 2013.

OSHA's last visit started on Mar 3, 2021 after an accident, in Draper.

Across those inspections OSHA issued 2 citation items: 2 serious.

OSHA proposed $2,300 in penalties. After settlements and reviews the total is $1,150, down 50%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Haemonetics Corp averages $625 over 1 cited inspection in that time.

Haemonetics Corp also files yearly injury logs with OSHA, summarized below.

Haemonetics Corp: OSHA citation items per year, 2013 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites Haemonetics Corp again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345179311 OPENED MAR 3, 2021Closed

Accident · Partial · Safety · 144 employees at the site · Closed Apr 5, 2021

12046 S Lone Peak Pkwy, Draper, UT 84020 · Surgical Appliance and Supplies Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343876561 OPENED MAR 18, 2019Closed

Planned · Partial · Safety · 193 employees at the site · Closed Mar 29, 2019

12046 S Lone Peak Pkwy, Draper, UT 84020 · Surgical Appliance and Supplies Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343097440 OPENED APR 23, 2018Closed

Complaint · Partial · Safety · 26 employees at the site · Closed Jun 18, 2018

12046 S Lone Peak Pkwy, Draper, UT 84020 · Surgical Appliance and Supplies Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Serious$1,250$625May 31, 2018Final

Inspection 343107330 OPENED APR 23, 2018Open

Complaint · Partial · Safety · 175 employees at the site · Open

12046 S Lone Peak Pkwy, Draper, UT 84020 · Surgical Appliance and Supplies Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 340703933 OPENED JUN 5, 2015Closed

Referral · Partial · Health · 180 employees at the site · Closed Jul 15, 2015

12046 S Lone Peak Pkwy, Draper, UT 84020 · Surgical Appliance and Supplies Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316935105 OPENED AUG 15, 2013Closed

Complaint · Partial · Safety · 170 employees at the site · Closed Sep 21, 2013

12046 Lone Peak Pkwy, Draper, UT 84020 · Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316929975 OPENED APR 9, 2013Closed

Referral · Partial · Safety · 165 employees at the site · Closed May 21, 2013

12046 Lone Peak Pkwy, Draper, UT 84020 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(a)(3) · Exit routes
Serious$1,050$525Apr 18, 2013Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Draper site logged 2 recordable injuries or illnesses among about 58 workers: 4.0 per 100 full-time workers, against a median of 1.1 for its industry. Those cases cost 4 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Haemonetics - Draper
Draper · 2023
58 214.01.1

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(7)(i)(a)

(A) Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.

29 CFR 1910.37 · Exit routes

29 CFR 1910.37(a)(3)

(3) Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level.

Other surgical appliance and supplies manufacturing employers in Utah

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.