Inspection 346986722 OPENED SEP 20, 2023Closed
2224 Rice Blvd, Houston, TX 77005 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Halcon Group has 2 OSHA inspections on record in Texas, the first in 2023.
OSHA's last visit started on Sep 20, 2023 to follow up on an earlier case, in Houston.
Across those inspections OSHA issued 5 citation items: 5 serious.
OSHA proposed $16,073 in penalties and the amount has not been reduced.
Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Halcon Group averages $16,073 over 1 cited inspection in that time.
Texas · latest 90 days of OSHA records
393employers cited
55 of them in the same industry
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch Halcon Group and get notified the morning OSHA posts a new citation for it.
Watch this company2224 Rice Blvd, Houston, TX 77005 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2224 Rice Blvd, Houston, TX 77005 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements |
Serious | $4,465 | $4,465 | Jun 16, 2023 | Final |
| Citation 1, item 1b 29 CFR 1926.502(b)(2) · Fall protection systems |
Serious | $0 | $0 | Jun 16, 2023 | Final |
| Citation 1, item 2 29 CFR 1926.451(f)(3) · Scaffolds, general requirements |
Serious | $2,678 | $2,678 | Jun 16, 2023 | Final |
| Citation 1, item 3 29 CFR 1926.452(j)(2) · Rules for each type of scaffold |
Serious | $4,465 | $4,465 | Jun 16, 2023 | Final |
| Citation 1, item 4 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $4,465 | $4,465 | Jun 16, 2023 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(b)(5)(ii)
(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.
29 CFR 1926.451(f)(3)
(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.
29 CFR 1926.452(j)(2)
(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.