OSHA SearchOSHA records by employer

Hamilton Builders, LLC: OSHA inspections and violations

Oklahoma City, Oklahoma · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

4inspections
6citation items
$5,320current penalties
Mar 18, 2025last inspection

Since 2019, OSHA inspectors have visited Hamilton Builders, LLC in Oklahoma 4 times.

The most recent inspection opened on Mar 18, 2025 as a planned inspection, in Oklahoma City.

In all, OSHA issued 6 citation items: 6 serious.

The proposed penalties came to $8,866; today they stand at $5,320, 40% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Hamilton Builders, LLC averages $5,320 across 1 cited inspection.

Hamilton Builders, LLC: OSHA citation items per year, 2019 to 2025
Citation items per year, by inspection date.

Oklahoma · latest 90 days of OSHA records

61employers cited

Get notified the morning OSHA posts each new citation in Oklahoma: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oklahoma

Checking a subcontractor, a client or your own company? Watch Hamilton Builders, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348117599 OPENED MAR 18, 2025Closed

Planned · Partial · Safety · 1 employee at the site · Closed Mar 25, 2025

2115 Grand Blvd, Oklahoma City, OK 73111 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347908683 OPENED DEC 2, 2024Closed

Planned · Partial · Safety · 20 employees at the site · Closed Jan 3, 2025

2101 Ne Grand Ave., Oklahoma City, OK 73111 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347045031 OPENED OCT 19, 2023Closed

Programmed other · Partial · Safety · 40 employees at the site · Closed Oct 23, 2023

11238 N Pennsylvania Ave, Oklahoma City, OK 73120 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344178579 OPENED JUL 24, 2019Closed

Unprogrammed other · Partial · Safety · 2 employees at the site · Closed Dec 16, 2019

9701 N. Council Rd., Oklahoma City, OK 73162 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$3,410$2,046Oct 18, 2019Final
Citation 1, item 1b
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$0$0Oct 18, 2019Final
Citation 1, item 2a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,410$2,046Oct 18, 2019Final
Citation 1, item 2b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Oct 18, 2019Final
Citation 1, item 2c
29 CFR 1926.451(b)(5)(i) · Scaffolds, general requirements
Serious$0$0Oct 18, 2019Final
Citation 1, item 3
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$2,046$1,228Oct 18, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(5)(i)

(5)(i) Each end of a platform 10 feet or less in length shall not extend over its support more than 12 inches (30 cm) unless the platform is designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.451(c)(1)

(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:

29 CFR 1926.451(c)(2)(i)

(i) Footings shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.