OSHA SearchOSHA records by employer

Hammonasset Construction, LLC: OSHA inspections and violations

Windsor, Connecticut · Site Preparation Contractors · NAICS 238910

2inspections
9citation items
$24,584current penalties
Mar 13, 2024last inspection

Hammonasset Construction, LLC has 2 OSHA inspections on record in Connecticut, the first in 2007.

OSHA's last visit started on Mar 13, 2024 on a referral, in Bridgeport.

Across those inspections OSHA issued 9 citation items: 2 serious and 7 other-than-serious.

OSHA proposed $58,460 in penalties. After settlements and reviews the total is $24,584, down 58%.

Most often, OSHA cited 1926.1203, confined spaces in construction: general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Hammonasset Construction, LLC averages $22,584 over 1 cited inspection in that time.

Hammonasset Construction, LLC: OSHA citation items per year, 2007 to 2024
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

84employers cited

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch Hammonasset Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347342347 OPENED MAR 13, 2024Closed

Referral · Partial · Health · 6 employees at the site · Closed Nov 6, 2024

600 Lindley Street Island Brook And Capitol Avenue Intersection, Bridgeport, CT 06606 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.55(a)(2) · Gases, vapors, fumes, dusts, and mists
Other-than-serious$11,292$11,292Sep 5, 2024Final
Citation 1, item 2a
29 CFR 1926.1203(d) · Confined Spaces in Construction: general requirements
Other-than-serious$11,292$11,292Sep 5, 2024Final
Citation 1, item 2b
29 CFR 1926.1203(a) · Confined Spaces in Construction: general requirements
Other-than-serious$0$0Sep 5, 2024Final
Citation 1, item 2c
29 CFR 1926.1203(b)(1) · Confined Spaces in Construction: general requirements
Other-than-serious$0$0Sep 5, 2024Final
Citation 1, item 2d
29 CFR 1926.1204(c)(4) · Permit-required confined space program
Other-than-serious$11,292$0Sep 5, 2024Final
Citation 1, item 2e
29 CFR 1926.1204(i) · Permit-required confined space program
Other-than-serious$11,292$0Sep 5, 2024Final
Citation 1, item 2f Other-than-serious$11,292$0Sep 5, 2024Final

Inspection 310184551 OPENED APR 28, 2007Closed

Referral · Partial · Safety · 3 employees at the site · Closed Jan 16, 2009

103 Rainbow Road, Windsor, CT 06095 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Apr 28, 2007: Employee shocked when excavator bucket strikes power line

On April 28, 2007, Employee #1 was standing near to where a coworker was operati ng an excavator. The coworker was raising the bucket when it struck energized ov erhead power lines. Employee #1 sustained an electric shock and was transported to a local hospital with non life threatening injuries.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1a
29 CFR 1926.21(b)(2) · Construction safety training
Serious$2,000$2,000Jan 7, 2008Closed
Citation 2, item 1b Serious$0$0Jan 7, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1203 · Confined Spaces in Construction: general requirements

29 CFR 1926.1203(a)

(a) Before it begins work at a worksite, each employer must ensure that a competent person identifies all confined spaces in which one or more of the employees it directs may work, and identifies each space that is a permit space, through consideration and evaluation of the elements of that space, including testing as necessary.

29 CFR 1926.1203(b)(1)

(1) Inform exposed employees by posting danger signs or by any other equally effective means, of the existence and location of, and the danger posed by, each permit space; and

29 CFR 1926.1203(d)

(d) If any employer decides that employees it directs will enter a permit space, that employer must have a written permit space program that complies with § 1926.1204 implemented at the construction site. The written program must be made available prior to and during entry operations for inspection by employees and their authorized representatives.

29 CFR 1926.1204 · Permit-required confined space program

29 CFR 1926.1207 · Training

29 CFR 1926.21 · Construction safety training

29 CFR 1926.55 · Gases, vapors, fumes, dusts, and mists

29 CFR 1926.600 · Equipment

Other site preparation contractors employers in Connecticut

Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.