Hanwha Q Cells USA Inc.: OSHA inspections and violations

Dalton, Georgia · Solar Electric Power Generation · NAICS 221114

13inspections
10citation items
$95,239current penalties
Nov 9, 2026last inspection

OSHA has inspected Hanwha Q Cells USA Inc. 13 times in Georgia since 2019.

The latest one began on Nov 9, 2026 on a referral, in Dalton; the case is still open.

Those inspections ended with 10 citation items: 5 serious, 1 repeat and 4 other-than-serious.

Penalties were first proposed at $160,283 and now stand at $95,239, 41% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 5 items under 1910.147.

How that compares: the median penalty per cited inspection for utility employers since 2015 is $0, and Hanwha Q Cells USA Inc. averages $15,873 (6 cited inspections).

Hanwha Q Cells USA Inc. also files yearly injury logs with OSHA, summarized below.

It reported 4 severe injuries to OSHA since 2015.

Hanwha Q Cells USA Inc.: OSHA citation items per year, 2019 to 2026
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

157employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Hanwha Q Cells USA Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Hanwha Q Cells USA Inc. at 2 sites in 2 states. Together they've had 14 inspections and $111,789 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 2 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 349282244 OPENED NOV 9, 2026Open

Referral · Partial · Safety · 1,652 employees at the site · Open

300 Nexus Dr., Dalton, GA 30721 · Semiconductor and Related Device Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 348820416 OPENED FEB 27, 2026Closed

Referral · Partial · Safety · 300 employees at the site · Closed Sep 22, 2026

300 Nexus Drive, Dalton, GA 30721 · Solar Electric Power Generation · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Other-than-serious$16,550$9,000Aug 11, 2026Final

Inspection 348747890 OPENED FEB 13, 2026Closed

Referral · Partial · Safety · 400 employees at the site · Closed Aug 4, 2026

300 Nexus Dr., Dalton, GA 30721 · Solar Electric Power Generation · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 348193541 OPENED APR 21, 2025Closed

Referral · Partial · Safety · 1,744 employees at the site · Closed Dec 15, 2025

300 Nexus Drive, Dalton, GA 30721 · Semiconductor and Related Device Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$16,550$9,930Oct 7, 2025Final

Inspection 347867509 OPENED OCT 17, 2024Closed

Complaint · Partial · Safety · 826 employees at the site · Closed Feb 25, 2025

300 Nexus Drive, Dalton, GA 30721 · Solar Electric Power Generation · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347749319 OPENED SEP 11, 2024Closed

Referral · Partial · Safety · 300 employees at the site · Closed Mar 16, 2026

300 Nexus Drive, Dalton, GA 30721 · Solar Electric Power Generation · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346624950 OPENED APR 11, 2023Closed

Referral · Partial · Safety · 826 employees at the site · Closed Oct 4, 2023

300 Nexus Drive, Dalton, GA 30721 · Semiconductor and Related Device Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345904130 OPENED APR 18, 2022Closed

Referral · Partial · Safety · 500 employees at the site · Closed Mar 6, 2023

300 Nexus Dr., Dalton, GA 30721 · Solar Electric Power Generation · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Serious$14,502$8,701Sep 19, 2022Final
Citation 1, item 2
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Repeat$79,761$47,856Sep 19, 2022Final
5 older inspections

Inspection 345204564 OPENED MAR 18, 2021Closed

Follow-up · Partial · Health · 720 employees at the site · Closed Aug 31, 2021

300 Nexus Drive, Dalton, GA 30721 · Semiconductor and Related Device Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344852074 OPENED JUL 24, 2020Closed

Referral · Partial · Safety · 600 employees at the site · Closed Sep 9, 2020

300 Nexus Dr, Dalton, GA 30721 · Solar Electric Power Generation · OSHA's record · Phone and website on Google Maps

Incident on Jul 19, 2020: Employee amputates finger while troubleshooting assembly mac

At 5:00 p.m. on July 19, 2020, an employee started a tabber assembly machine to ensure that it was operating within a preset parameter as part of a troubleshooting process. The employee bypassed a door panel safety sensor in order to expedite visual inspection. With one of the panel doors open, the employee attempted to adjust a wire base by placing his right hand underneath it. The wire base came down on his hand and partially amputated his middle finger, requiring hospitalization.

No citations from this inspection.

Inspection 344630389 OPENED FEB 10, 2020Closed

Complaint · Partial · Health · 403 employees at the site · Closed Jul 14, 2020

300 Nexus Drive, Dalton, GA 30721 · Semiconductor and Related Device Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$8,193$4,916Jun 15, 2020Final
Citation 1, item 2
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$5,783$3,470Jun 15, 2020Final

Inspection 343933883 OPENED APR 9, 2019Closed

Unprogrammed related · Partial · Safety · 600 employees at the site · Closed Jul 9, 2019

300 Nexus Dr., Dalton, GA 30721 · Semiconductor and Related Device Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.36(g)(2) · Exit route design
Other-than-serious$0$0Jun 3, 2019Final

Inspection 343825956 OPENED MAR 4, 2019Closed

Complaint · Partial · Safety · 450 employees at the site · Closed Nov 19, 2019

300 Nexus Dr., Dalton, GA 30721 · Solar Electric Power Generation · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$9,472$5,683Aug 23, 2019Final
Citation 1, item 2
29 CFR 1910.147(c)(5)(i) · Lockout/tagout
Serious$9,472$5,683Aug 23, 2019Final
Citation 2, item 1
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Other-than-serious$0$0Aug 23, 2019Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Dalton site logged 38 recordable injuries or illnesses among about 1,652 workers: 2.6 per 100 full-time workers, against a median of 0.5 for its industry. Those cases cost 52 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Hanwha Q Cells USA, Inc.
Dalton · 2025
1,652 38102.60.5

Included with any plan: 6 more yearly logs from these sites, back to 2019, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 4 reports on file.

Apr 14, 2025, Dalton: Amputation · amputations, avulsions, enucleations unspecified · finger or thumb tip(s), nail(s)

On April 14, 2025, an employee was clearing a jam in a framer machine. The machine caught and pinched the employee's right index fingertip, resulting in amputation of the fingertip.

Dec 10, 2024, Dalton: Hospitalization · fractures · foot (feet), toe(s) unspecified

On December 10, 2024, an employee was working from a 6-foot ladder. He fell off the ladder from 3 feet above the ground, suffering a broken right foot.

Mar 30, 2023, Dalton: Amputation · amputations · fingertip(s)

On March 30, 2023, employees were testing the strength of a magnet on a machine during a training operation. The machine was activated and amputated the employee's left little fingertip.

Jul 19, 2020, Dalton: Hospitalization, amputation · amputations · fingertip(s)

An employee was checking on an error. He went to level off the tabber equipment when the machine turned on, amputating his right middle fingertip.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(5)(i)

(5) Protective materials and hardware. (i) Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware shall be provided by the employer for isolating, securing or blocking of machines or equipment from energy sources.

29 CFR 1910.147(c)(6)(ii)

(ii) The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.305 · Electrical wiring methods