Inspection 347457640 OPENED MAY 2, 2024Closed
749 Goodman Rd W, Horn Lake, MS 38637 · Limited-Service Restaurants · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Quitman, Mississippi · Limited-Service Restaurants · NAICS 722513
Hardee's has 3 OSHA inspections on record in Mississippi, the first in 2016.
OSHA's last visit started on May 2, 2024 after a complaint, in Horn Lake.
Across those inspections OSHA issued 4 citation items: 2 serious and 2 other-than-serious.
OSHA proposed $3,362 in penalties. After settlements and reviews the total is $2,017, down 40%.
Most often, OSHA cited 1910.305, electrical wiring methods (3 items).
For context, across all hotel and restaurant employers the median penalty per cited inspection since 2015 is $1,350. Hardee's averages $2,017 over 1 cited inspection in that time.
Want to know if OSHA cites Hardee's again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company749 Goodman Rd W, Horn Lake, MS 38637 · Limited-Service Restaurants · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2403 Hwy 90, Gautier, MS 39553 · Limited-Service Restaurants · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
302 North Archusa Ave., Quitman, MS 39355 · Food Services and Drinking Places · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.304(b)(3)(i) · Grounding and circuit protection |
Serious | $1,817 | $1,090 | Nov 9, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $1,545 | $927 | Nov 9, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Nov 9, 2016 | Final |
| Citation 2, item 2 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Nov 9, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.304(b)(3)(i)
(3) Ground-fault circuit interrupter protection for personnel. (i) All 125-volt, single-phase, 15- and 20-ampere receptacles installed in bathrooms or on rooftops shall have ground-fault circuit-interrupter protection for personnel.
29 CFR 1910.305(b)(2)(i)
(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.
29 CFR 1910.305(g)(2)(ii)
(ii) Flexible cords may be used only in continuous lengths without splice or tap. Hard-service cord and junior hard-service cord No. 14 and larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.