Harmar Mobility, LLC.: OSHA inspections and violations

Sarasota, Florida · All Other Miscellaneous Fabricated Metal Product Manufacturing · NAICS 332999

1inspections
7citation items
$6,519current penalties
Jun 7, 2017last inspection

OSHA has inspected Harmar Mobility, LLC. once in Florida.

The inspection began on Jun 7, 2017 after a complaint, in Sarasota.

That inspection ended with 7 citation items: 4 serious and 3 other-than-serious.

Penalties were first proposed at $6,519 and still stand at $6,519.

Hexavalent chromium comes up most often in these citations: 3 items under 1910.1026.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Harmar Mobility, LLC. averages $6,519 (1 cited inspection).

Harmar Mobility, LLC.: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Harmar Mobility, LLC. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342389590 OPENED JUN 7, 2017Closed

Complaint · Partial · Health · 105 employees at the site · Closed Jan 2, 2018

2075 47th Street, Sarasota, FL 34234 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$6,519$6,519Nov 7, 2017Final
Citation 1, item 1b
29 CFR 1910.1026(c) · Hexavalent chromium
Serious$0$0Nov 7, 2017Final
Citation 1, item 1c
29 CFR 1910.1026(d)(1) · Hexavalent chromium
Serious$0$0Nov 7, 2017Final
Citation 1, item 1d
29 CFR 1910.1026(g)(1)(iv) · Hexavalent chromium
Serious$0$0Nov 7, 2017Final
Citation 2, item 1
29 CFR 1910.252(a)(2)(vii) · Welding fire safety
Other-than-serious$0$0Nov 7, 2017Final
Citation 2, item 2
29 CFR 1910.252(a)(2)(ix) · Welding fire safety
Other-than-serious$0$0Nov 7, 2017Final
Citation 2, item 3
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$0$0Nov 7, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1026 · Hexavalent chromium

29 CFR 1910.1026(c)

(c) Permissible exposure limit (PEL). The employer shall ensure that no employee is exposed to an airborne concentration of chromium (VI) in excess of 5 micrograms per cubic meter of air (5 µgm/m 3), calculated as an 8-hour time-weighted average (TWA).

29 CFR 1910.1026(d)(1)

(d) Exposure determination—(1) General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section.

29 CFR 1910.1026(g)(1)(iv)

(iv) Work operations where employees are exposed above the PEL for fewer than 30 days per year, and the employer has elected not to implement engineering and work practice controls to achieve the PEL; or

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.305 · Electrical wiring methods

Other all other miscellaneous fabricated metal product manufacturing employers in Florida

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.