OSHA SearchOSHA records by employer

Harper & Company Builders, Inc.: OSHA inspections and violations

Douglas, Georgia · Commercial and Institutional Building Construction · NAICS 236220

7inspections
16citation items
$9,571current penalties
Aug 17, 2016last inspection

Harper & Company Builders, Inc. has 7 OSHA inspections on record in Georgia, the first in 1998.

OSHA's last visit started on Aug 17, 2016 as a planned inspection, in Waycross.

Across those inspections OSHA issued 16 citation items: 12 serious and 4 other-than-serious.

OSHA proposed $15,993 in penalties. After settlements and reviews the total is $9,571, down 40%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Harper & Company Builders, Inc. averages $3,635 over 1 cited inspection in that time.

Harper & Company Builders, Inc.: OSHA citation items per year, 1998 to 2016
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

156employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Harper & Company Builders, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341708667 OPENED AUG 17, 2016Closed

Planned · Complete · Safety · 6 employees at the site · Closed Nov 15, 2016

1701 Carswell Ave, Waycross, GA 31503 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,029$1,817Oct 28, 2016Final
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,029$1,817Oct 28, 2016Final

Inspection 338600034 OPENED JAN 30, 2013Closed

Planned · Complete · Safety · 4 employees at the site · Closed May 30, 2013

3rd St. And Railroad St., Unadilla, GA 31091 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.602(a)(2)(i) · Earthmovers and forklifts in construction
Serious$1,360$816Apr 25, 2013Final
Citation 1, item 2a
29 CFR 1926.602(a)(9)(i) · Earthmovers and forklifts in construction
Serious$1,700$1,020Apr 25, 2013Final
Citation 1, item 2b
29 CFR 1926.602(a)(9)(ii) · Earthmovers and forklifts in construction
Serious$0$0Apr 25, 2013Final
Citation 2, item 1
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$0$0Apr 25, 2013Final

Inspection 312526403 OPENED MAY 12, 2009Closed

Planned · Complete · Safety · 2 employees at the site · Closed May 18, 2009

1750 Hwy 341 N, Fort Valley, GA 31030 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310992649 OPENED APR 1, 2009Closed

Planned · Partial · Safety · 5 employees at the site · Closed Apr 7, 2009

825 Thompson Drive, Douglas, GA 31533 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307409318 OPENED AUG 26, 2005Closed

Unprogrammed related · Complete · Safety · 8 employees at the site · Closed Mar 14, 2006

904 Mlk, Ailey, GA 30410 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$700$420Feb 23, 2006Closed
Citation 1, item 3
29 CFR 1926.405(d) · Job-site wiring
Serious$875$525Feb 23, 2006Closed
Citation 1, item 4
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$525$315Feb 23, 2006Closed
Citation 1, item 5
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$700$420Feb 23, 2006Closed
Citation 1, item 6
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$700$420Feb 23, 2006Closed
Citation 1, item 7
29 CFR 1926.760(a)(1) · Fall protection
Serious$2,500$1,500Feb 23, 2006Closed
Citation 2, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$0$0Feb 23, 2006Closed
Citation 2, item 2
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Other-than-serious$0$0Feb 23, 2006Closed

Inspection 300649837 OPENED FEB 19, 1999Closed

Planned · Complete · Safety · 14 employees at the site · Closed Feb 19, 1999

2033 Hwy 158 West, Douglas, GA 31533 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.200(c)(1) · Accident prevention signs and tags
Other-than-serious$0$0Jun 28, 2000Closed

Inspection 300647997 OPENED MAY 20, 1998Closed

Referral · Partial · Safety · 4 employees at the site · Closed Jun 15, 1998

Intersection Of Hwy 32 & S. Liberty St., Nicholls, GA 31555 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$875$500May 27, 1998Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.200 · Accident prevention signs and tags

29 CFR 1926.200(c)(1)

(c) Caution signs. (1) Caution signs shall be used only to warn against potential hazards or to caution against unsafe practices, and shall follow the specifications illustrated in Figure 4 of ANSI Z35.1-1968 or in Figures 1 to 13 of ANSI Z535.2-2011, incorporated by reference in § 1926.6.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 1926.760 · Fall protection

Other commercial and institutional building construction employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.