Inspection 344515432 OPENED DEC 17, 2019Closed
161 Colson Lane, Mullica Hill, NJ 08062 · Facilities Support Services · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Mullica Hill, New Jersey · Facilities Support Services · NAICS 561210
Since 2015, OSHA inspectors have visited Harrison Township DPW in New Jersey 4 times.
The most recent inspection opened on Dec 17, 2019 to follow up on an earlier case, in Mullica Hill.
In all, OSHA issued 32 citation items: 22 serious and 10 other-than-serious.
The penalties, $81,200 in total, stand where OSHA first set them.
The rule cited most here is 1910.147 (lockout/tagout), 4 times.
Among staffing, cleaning and waste services employers, the typical cited inspection since 2015 ends with a $2,208 penalty. Harrison Township DPW averages $40,600 across 2 cited inspections.
New Jersey · latest 90 days of OSHA records
264employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New Jersey
Checking a subcontractor, a client or your own company? Watch Harrison Township DPW and get notified the morning OSHA posts a new citation for it.
Watch this company161 Colson Lane, Mullica Hill, NJ 08062 · Facilities Support Services · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
161 Colson Lane, Mullica Hill, NJ 08062 · Facilities Support Services · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.37(b)(2) · Exit routes |
Serious | $4,200 | $4,200 | Oct 23, 2019 | Final |
| Citation 1, item 2 29 CFR 1910.37(b)(4) · Exit routes |
Serious | $4,200 | $4,200 | Oct 23, 2019 | Final |
| Citation 1, item 3 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Serious | $4,200 | $4,200 | Oct 23, 2019 | Final |
| Citation 1, item 4 29 CFR 1910.176(b) · Material storage and aisles |
Serious | $4,200 | $4,200 | Oct 23, 2019 | Final |
| Citation 1, item 5 29 CFR 1910.176(c) · Material storage and aisles |
Serious | $4,200 | $4,200 | Oct 23, 2019 | Final |
| Citation 1, item 6a 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Serious | $4,200 | $4,200 | Oct 23, 2019 | Final |
| Citation 1, item 6b 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $0 | $0 | Oct 23, 2019 | Final |
| Citation 1, item 7a 29 CFR 1910.217(b)(4)(i) · Mechanical power presses |
Serious | $4,900 | $4,900 | Oct 23, 2019 | Final |
| Citation 1, item 7b 29 CFR 1910.217(c)(1)(i) · Mechanical power presses |
Serious | $0 | $0 | Oct 23, 2019 | Final |
| Citation 1, item 8 29 CFR 1910.334(a)(2)(i) · Using electrical equipment |
Serious | $4,200 | $4,200 | Oct 23, 2019 | Final |
| Citation 1, item 9 29 CFR 1910.305(j)(2)(iv) · Electrical wiring methods |
Serious | $4,200 | $4,200 | Oct 23, 2019 | Final |
| Citation 1, item 10 29 CFR 1910.305(a)(2)(i) · Electrical wiring methods |
Serious | $4,200 | $4,200 | Oct 23, 2019 | Final |
| Citation 1, item 11 29 CFR N.J.S.A. 34:6A-33(A) |
Serious | $4,200 | $4,200 | Oct 23, 2019 | Final |
| Citation 2, item 1 29 CFR 1910.147(c)(4)(ii) · Lockout/tagout |
Other-than-serious | $700 | $700 | Oct 23, 2019 | Final |
| Citation 2, item 2 29 CFR 1910.147(c)(6)(ii) · Lockout/tagout |
Other-than-serious | $700 | $700 | Oct 23, 2019 | Final |
| Citation 2, item 3 29 CFR 1910.1200(a)(1) · Hazard communication |
Other-than-serious | $700 | $700 | Oct 23, 2019 | Final |
151 Colson Lane, Mullica Hill, NJ 08062 · Facilities Support Services · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
151 Colson Lane, Mullica Hill, NJ 08062 · Facilities Support Services · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.101(b) · Compressed gases (general requirements) |
Serious | $2,800 | $2,800 | May 12, 2015 | Final |
| Citation 1, item 2 29 CFR 1910.106(g)(9) · Flammable liquids |
Serious | $2,800 | $2,800 | May 12, 2015 | Final |
| Citation 1, item 3 29 CFR 1910.125(f)(3)(iii) · Additional requirements for dipping and coating operations that use flammable liquids or liquids with flashpoints greater than 199.4 °F (93 °C) |
Serious | $2,800 | $2,800 | May 12, 2015 | Final |
| Citation 1, item 4 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $2,800 | $2,800 | May 12, 2015 | Final |
| Citation 1, item 5 29 CFR 1910.212(b) · Machine guarding |
Serious | $2,800 | $2,800 | May 12, 2015 | Final |
| Citation 1, item 6 29 CFR 1910.213(b)(3) · Woodworking machinery |
Serious | $3,500 | $3,500 | May 12, 2015 | Final |
| Citation 1, item 7 29 CFR 1910.213(c)(1) · Woodworking machinery |
Serious | $3,500 | $3,500 | May 12, 2015 | Final |
| Citation 1, item 8 29 CFR 1910.213(h)(4) · Woodworking machinery |
Serious | $2,800 | $2,800 | May 12, 2015 | Final |
| Citation 1, item 9 29 CFR 1926.601(b)(4) · Motor vehicles |
Serious | $3,500 | $3,500 | May 12, 2015 | Final |
| Citation 2, item 1 29 CFR 1910.106(g)(8) · Flammable liquids |
Other-than-serious | $700 | $700 | May 12, 2015 | Final |
| Citation 2, item 2 29 CFR 1910.125(e)(5) · Additional requirements for dipping and coating operations that use flammable liquids or liquids with flashpoints greater than 199.4 °F (93 °C) |
Other-than-serious | $700 | $700 | May 12, 2015 | Final |
| Citation 2, item 3 29 CFR 1910.145(c)(3) · Specifications for accident prevention signs and tags |
Other-than-serious | $700 | $700 | May 12, 2015 | Final |
| Citation 2, item 4 29 CFR 1910.147(c)(4)(ii) · Lockout/tagout |
Other-than-serious | $700 | $700 | May 12, 2015 | Final |
| Citation 2, item 5 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Other-than-serious | $700 | $700 | May 12, 2015 | Final |
| Citation 2, item 6 29 CFR 1910.244(a)(2)(vi) · Other portable tools and equipment |
Other-than-serious | $700 | $700 | May 12, 2015 | Final |
| Citation 2, item 7 29 CFR N.J.A.C. 12:100-7.5(A) |
Other-than-serious | $700 | $700 | May 12, 2015 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.101(b)
(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.
29 CFR 1910.106(g)(8)
(8) Sources of ignition. In addition to the previous restrictions of this paragraph, the following shall apply: There shall be no smoking or open flames in the areas used for fueling, servicing fuel systems for internal combustion engines, receiving or dispensing of flammable liquids. Conspicuous and legible signs prohibiting smoking shall be posted within sight of the customer being served. The motors of all equipment being fueled shall be shut off during the fueling operation.
29 CFR 1910.106(g)(9)
(9) Fire control. Each service station shall be provided with at least one fire extinguisher having a minimum approved classification of 6 B, C, located so that an extinguisher, will be within 75 feet of each pump, dispenser, underground fill pipe opening, and lubrication or service room.
Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.