Inspection 346141955 OPENED AUG 3, 2022Closed
3370 High Point Blvd, Bethlehem, PA 18017 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Bethlehem, Pennsylvania · Masonry Contractors · NAICS 238140
Since 2008, OSHA inspectors have visited Hartman Masonry, Inc. in Pennsylvania 3 times.
The most recent inspection opened on Aug 3, 2022 as a planned inspection, in Bethlehem.
In all, OSHA issued 5 citation items: 4 serious and 1 other-than-serious.
The penalties, $4,728 in total, stand where OSHA first set them.
The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Hartman Masonry, Inc. averages $3,078 across 1 cited inspection.
Pennsylvania · latest 90 days of OSHA records
277employers cited
6 of them in the same industry
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch Hartman Masonry, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company3370 High Point Blvd, Bethlehem, PA 18017 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
834 Eaton Avenue, Bethlehem, PA 18018 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Other-than-serious | $3,078 | $3,078 | Sep 27, 2017 | Final |
Mickley & Macarthur Road, Whitehall, PA 18052 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $600 | $600 | Apr 2, 2008 | Closed |
| Citation 1, item 1b 29 CFR 1926.451(f)(7) · Scaffolds, general requirements |
Serious | $0 | $0 | Apr 2, 2008 | Closed |
| Citation 1, item 1c 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $0 | $0 | Apr 2, 2008 | Closed |
| Citation 1, item 2 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $1,050 | $1,050 | Apr 2, 2008 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(e)(1)
(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.
29 CFR 1926.451(f)(7)
(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.
29 CFR 1926.451(g)(1)
(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.