OSHA SearchOSHA records by employer

Hartness Drywall Inc: OSHA inspections and violations

Eugene, Oregon · Drywall and Insulation Contractors · NAICS 238310

6inspections
9citation items
$3,450current penalties
Apr 10, 2026last inspection

OSHA has inspected Hartness Drywall Inc 6 times in Oregon since 2007.

The latest one began on Apr 10, 2026 as a planned inspection, in Eugene; the case is still open.

Those inspections ended with 9 citation items: 7 serious and 2 other-than-serious.

Penalties were first proposed at $3,450 and still stand at $3,450.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Hartness Drywall Inc averages $1,050 (3 cited inspections).

Hartness Drywall Inc: OSHA citation items per year, 2007 to 2026
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

388employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Hartness Drywall Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348871880 OPENED APR 10, 2026Open

Planned · Complete · Safety · 2 employees at the site · Open

2980 Portland St, Eugene, OR 97402 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.452(w)(2) · Rules for each type of scaffold
Serious$1,457$1,457Jul 27, 2026Final

Inspection 347705691 OPENED MAY 17, 2024Closed

Accident · Partial · Health · 23 employees at the site · Closed Feb 25, 2025

90682 Link Rd, Eugene, OR 97402 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$1,383$1,383Sep 5, 2024Final

Inspection 341142891 OPENED DEC 23, 2015Closed

Planned · Complete · Safety · 15 employees at the site · Closed Aug 15, 2016

1150 W 1st St, Junction City, OR 97448 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(d) · Job-site wiring
Serious$210$210Jan 27, 2016Final
Citation 1, item 2
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Serious$100$100Jan 27, 2016Final

Inspection 315900167 OPENED JAN 27, 2012Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jan 27, 2012

265 S Garden Way, Eugene, OR 97401 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314788100 OPENED MAY 26, 2011Closed

Planned · Partial · Safety · 5 employees at the site · Closed Oct 6, 2011

1122 W 7th Ave, Eugene, OR 97402 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$300$300Jun 22, 2011Closed
Citation 1, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Jun 22, 2011Closed
Citation 1, item 1c
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Jun 22, 2011Closed

Inspection 310740956 OPENED NOV 16, 2007Closed

Planned · Complete · Safety · 8 employees at the site · Closed Apr 25, 2008

31335 Raisor Rd, Cottage Grove, OR 97424 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Dec 27, 2007Closed
Citation 1, item 2
29 CFR 1926.1060(a) · Ladder and stairway training
Other-than-serious$0$0Dec 27, 2007Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.1060(a)

(a) The employer shall provide a training program for each employee using ladders and stairways, as necessary. The program shall enable each employee to recognize hazards related to ladders and stairways, and shall train each employee in the procedures to be followed to minimize these hazards.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(d)

(d) Switchboards and panelboards. Switchboards that have any exposed live parts shall be located in permanently dry locations and accessible only to qualified persons. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons. Exposed blades of knife switches shall be dead when open.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 7030.740

Other drywall and insulation contractors employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.