OSHA SearchOSHA records by employer

Hartnett Electric, Inc: OSHA inspections and violations

Tampa, Florida · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
2citation items
$9,678current penalties
Aug 16, 2024last inspection

Hartnett Electric, Inc has one OSHA inspection on record in Florida.

OSHA opened it on Aug 16, 2024 on a referral, in Tampa.

From that inspection OSHA issued 2 citation items: 1 serious and 1 other-than-serious.

OSHA proposed $12,904 in penalties. After settlements and reviews the total is $9,678, down 25%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Hartnett Electric, Inc averages $9,678 over 1 cited inspection in that time.

It reported 1 severe injury to OSHA since 2015.

Hartnett Electric, Inc: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

318employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Hartnett Electric, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347692477 OPENED AUG 16, 2024Closed

Referral · Partial · Safety · 15 employees at the site · Closed Sep 10, 2024

Usf Bsn Building 12212 Usf Genshaft Dr., Tampa, FL 33620 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.28(a) · Personal protective equipment
Other-than-serious$6,452$4,839Aug 21, 2024Final
Citation 1, item 2
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$6,452$4,839Aug 21, 2024Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Aug 13, 2024, Tampa: Hospitalization · severe wounds, internal injuries and electrocution, electric shock · body systems and other part(s) of body

The injured employee was on the fifth step of an 8-foot ladder using wire cutters to show two other employees which wire was still hot in the junction box. The wire cutter penetrated the wire sheathing and the employee was shocked. The injured employee began to fall backward off the ladder and the other two employees were able to cushion his fall. The employee sustained a broken pelvic bone on the right side.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.28(a)

(a) The employer is responsible for requiring the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions or where this part indicates the need for using such equipment to reduce the hazards to the employees.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

Other electrical contractors and other wiring installation contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.