OSHA has inspected Hartzell Fan, Inc. 3 times in Ohio since 2012.
The latest one began on Mar 8, 2023 on a referral, in Piqua.
Those inspections ended with 14 citation items: 13 serious and 1 other-than-serious.
Penalties were first proposed at $104,007 and now stand at $34,369, 67% lower after settlements or reviews.
Lockout/tagout comes up most often in these citations: 7 items under 1910.147.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Hartzell Fan, Inc. averages $15,469 (1 cited inspection).
Hartzell Fan, Inc. also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Ohio · latest 90 days of OSHA records
263employers cited
Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.
Referral · Partial · Health · 160 employees at the site · Closed Mar 14, 2013
910 S. Downing St., Piqua, OH 45356 · Ventilation, Heating, Air-Conditioning, and Commercial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1a
29 CFR 1910.132(a) · Personal protective equipment, general requirements
29 CFR 1904.10(a) · Recording criteria for cases involving occupational hearing loss
Other-than-serious
$900
$900
Apr 13, 2012
Final
Inspection 331916239 OPENED FEB 14, 2012Closed
Planned · Partial · Safety · 160 employees at the site · Closed Mar 26, 2014
910 S. Downing St., Piqua, OH 45356 · Ventilation, Heating, Air-Conditioning, and Commercial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2018, the Piqua site logged 13 recordable injuries or illnesses among about 118 workers: 11.0 per 100 full-time workers, against a median of 2.4 for its industry. Those cases cost 9 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Hartzell Air Movement
Piqua · 2018
118
13
5
11.0
2.4
Included with any plan: 2 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1904.10 · Recording criteria for cases involving occupational hearing loss
29 CFR 1904.10(a)
(a) Basic requirement. If an employee's hearing test (audiogram) reveals that the employee has experienced a work-related Standard Threshold Shift (STS) in hearing in one or both ears, and the employee's total hearing level is 25 decibels (dB) or more above audiometric zero (averaged at 2000, 3000, and 4000 Hz) in the same ear(s) as the STS, you must record the case on the OSHA 300 Log.
29 CFR 1910.132 · Personal protective equipment, general requirements
29 CFR 1910.132(a)
(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.
(a) General requirements. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.
Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.