OSHA SearchOSHA records by employer

Haskins Underground Inc: OSHA inspections and violations

Kouts, Indiana · Water and Sewer Line and Related Structures Construction · NAICS 237110

1inspections
2citation items
$400current penalties
Aug 24, 2021last inspection

Haskins Underground Inc has one OSHA inspection on record in Indiana.

OSHA opened it on Aug 24, 2021 after a complaint, in Kouts, and the case has not closed yet.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $400 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.652, trench protection (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Haskins Underground Inc averages $400 over 1 cited inspection in that time.

Haskins Underground Inc: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

79employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch Haskins Underground Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345496301 OPENED AUG 24, 2021Open

Complaint · Partial · Safety · 5 employees at the site · Open

Field North Of 112 W 450 S, Kouts, IN 46347 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(g)(1)(ii) · Trench protection
Serious$200$200Nov 9, 2021Final
Citation 1, item 2
29 CFR 1926.652(g)(2) · Trench protection
Serious$200$200Nov 9, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(g)(1)(ii)

(ii) Shields shall be installed in a manner to restrict lateral or other hazardous movement of the shield in the event of the application of sudden lateral loads.

29 CFR 1926.652(g)(2)

(2) Additional requirement for shield systems used in trench excavations. Excavations of earth material to a level not greater than 2 feet (.61 m) below the bottom of a shield shall be permitted, but only if the shield is designed to resist the forces calculated for the full depth of the trench, and there are no indications while the trench is open of a possible loss of soil from behind or below the bottom of the shield.

Other water and sewer line and related structures construction employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.