OSHA SearchOSHA records by employer

Have a Bowl, LLC: OSHA inspections and violations

Hagerstown, Maryland · Bowling Centers · NAICS 713950

2inspections
14citation items
$1,000current penalties
Feb 3, 2023last inspection

Have a Bowl, LLC has 2 OSHA inspections on record in Maryland, the first in 2022.

OSHA's last visit started on Feb 3, 2023 on a referral, in Hagerstown.

Across those inspections OSHA issued 14 citation items: 10 serious and 4 other-than-serious.

OSHA proposed $3,200 in penalties. After settlements and reviews the total is $1,000, down 69%.

Most often, OSHA cited 1910.219, belts, pulleys and power-transmission parts (6 items).

For context, across all arts and recreation employers the median penalty per cited inspection since 2015 is $1,400. Have a Bowl, LLC averages $1,000 over 1 cited inspection in that time.

Have a Bowl, LLC: OSHA citation items per year, 2022 to 2023
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

182employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Have a Bowl, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346493174 OPENED FEB 3, 2023Closed

Referral · Partial · Health · 18 employees at the site · Closed Apr 14, 2023

19330 Leitersburg Pike, Hagerstown, MD 21742 · Bowling Centers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346249501 OPENED SEP 27, 2022Closed

Complaint · Partial · Safety · 18 employees at the site · Closed Jan 11, 2023

19330 Leitersburg Pike, Hagerstown, MD 21742 · Bowling Centers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(3)(ii) · Fall protection in general industry
Serious$900$250Dec 5, 2022Final
Citation 1, item 2a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$900$330Dec 5, 2022Final
Citation 1, item 2b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Dec 5, 2022Final
Citation 1, item 2c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Dec 5, 2022Final
Citation 1, item 3a
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Serious$1,400$420Dec 5, 2022Final
Citation 1, item 3b
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$0$0Dec 5, 2022Final
Citation 1, item 3c
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Dec 5, 2022Final
Citation 1, item 3d
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Dec 5, 2022Final
Citation 1, item 3e
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Dec 5, 2022Final
Citation 1, item 3f
29 CFR 1910.219(i)(1) · Belts, pulleys and power-transmission parts
Serious$0$0Dec 5, 2022Final
Citation 2, item 1
29 CFR 1910.28(b)(11)(ii) · Fall protection in general industry
Other-than-serious$0$0Dec 5, 2022Final
Citation 2, item 2
29 CFR 1910.29(b)(2)(i) · Fall protection systems in general industry
Other-than-serious$0$0Dec 5, 2022Final
Citation 2, item 3
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Other-than-serious$0$0Dec 5, 2022Final
Citation 2, item 4
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0Dec 5, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.147(c)(6)(ii)

(ii) The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.29 · Fall protection systems in general industry

Other bowling centers employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.