OSHA SearchOSHA records by employer

Hawkeye Construction LLC: OSHA inspections and violations

Baltimore, Maryland · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

1inspections
4citation items
$418current penalties
May 12, 2015last inspection

OSHA has inspected Hawkeye Construction LLC once in Maryland.

The inspection began on May 12, 2015 as a planned inspection, in Baltimore.

That inspection ended with 4 citation items: 2 serious and 2 other-than-serious.

Penalties were first proposed at $524 and now stand at $418, 20% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Hawkeye Construction LLC averages $418 (1 cited inspection).

Hawkeye Construction LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

194employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Hawkeye Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340623941 OPENED MAY 12, 2015Closed

Planned · Complete · Safety · 1 employee at the site · Closed Sep 2, 2015

1500-1506 Charles Street, Baltimore, MD 21230 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$262$209Aug 7, 2015Final
Citation 1, item 2
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$262$209Aug 7, 2015Final
Citation 2, item 1
29 CFR 1926.403(h) · Electrical equipment on job sites
Other-than-serious$0$0Aug 7, 2015Final
Citation 2, item 2
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Other-than-serious$0$0Aug 7, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(h)

(h) Identification of disconnecting means and circuits. Each disconnecting means required by this subpart for motors and appliances shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. These markings shall be of sufficient durability to withstand the environment involved.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(1)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.

29 CFR 1926.501 · Fall protection in construction

Other new multifamily housing construction (except for-sale builders) employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.