Inspection 343899332 OPENED MAR 29, 2019Closed
500 South Upper Street, Lexington, KY 40508 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
HB Masonry LLC has 4 OSHA inspections on record in Kentucky, the first in 2016.
OSHA's last visit started on Mar 29, 2019 on a referral, in Lexington.
Across those inspections OSHA issued 4 citation items: 4 serious.
OSHA proposed $15,400 in penalties. After settlements and reviews the total is $7,900, down 49%.
Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. HB Masonry LLC averages $3,950 over 2 cited inspections in that time.
Kentucky · latest 90 days of OSHA records
181employers cited
4 of them in the same industry
Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Kentucky
Checking a subcontractor, a client or your own company? Watch HB Masonry LLC and get notified the morning OSHA posts a new citation for it.
Watch this company500 South Upper Street, Lexington, KY 40508 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
369 E Main St, Lexington, KY 40507 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.451(a)(1) · Scaffolds, general requirements |
Serious | $5,600 | $3,000 | Nov 28, 2018 | Final |
| Citation 1, item 1b 29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements |
Serious | $0 | $0 | Nov 28, 2018 | Final |
150 Ab Chandler Place, Morehead, KY 40351 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(f)(3) · Scaffolds, general requirements |
Serious | $4,900 | $2,450 | Jan 5, 2017 | Final |
| Citation 1, item 2 29 CFR 1926.451(f)(4) · Scaffolds, general requirements |
Serious | $4,900 | $2,450 | Jan 5, 2017 | Final |
550 S Limestone, Lexington, KY 40508 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(a)(1)
(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.
29 CFR 1926.451(c)(1)(ii)
(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).
29 CFR 1926.451(f)(3)
(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.
Alert subscribers get notified of each newly cited employer in Kentucky the morning it is posted. See the alert plans.