El Paso, Texas · Structural Steel and Precast Concrete Contractors · NAICS 238120

3inspections
6citation items
$8,552current penalties
Oct 11, 2022last inspection

Since 2010, OSHA inspectors have visited HB Welding & Fabricating in Texas 3 times.

The most recent inspection opened on Oct 11, 2022 as a planned inspection, in El Paso.

In all, OSHA issued 6 citation items: 5 serious and 1 other-than-serious.

The proposed penalties came to $16,478; today they stand at $8,552, 48% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. HB Welding & Fabricating averages $2,776 across 2 cited inspections.

HB Welding & Fabricating: OSHA citation items per year, 2010 to 2022
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

401employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch HB Welding & Fabricating and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346277353 OPENED OCT 11, 2022Closed

Planned · Partial · Safety · 4 employees at the site · Closed Mar 19, 2026

6470 N. Desert Dr., El Paso, TX 79911 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Other-than-serious$2,678$1,000Feb 15, 2023Final
Citation 1, item 3
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$3,572$1,428Feb 15, 2023Final
Citation 1, item 4
29 CFR 1926.760(b)(3) · Fall protection
Serious$5,358$2,124Feb 15, 2023Final

Inspection 341341030 OPENED MAR 22, 2016Closed

Unprogrammed other · Partial · Safety · 3 employees at the site · Closed May 11, 2017

Tiendas De Zaragosa 3560 N. Zaragosa, El Paso, TX 79938 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$1,870$1,000Jul 1, 2016Final

Inspection 313497802 OPENED APR 26, 2010Closed

Planned · Partial · Safety · 8 employees at the site · Closed May 15, 2013

5750 Doniphan, El Paso, TX 79932 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.351(b)(4) · Arc welding and cutting
Serious$1,500$1,500Oct 5, 2010Closed
Citation 1, item 2
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,500$1,500Oct 5, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.351 · Arc welding and cutting

29 CFR 1926.351(b)(4)

(4) Cables in need of repair shall not be used. When a cable, other than the cable lead referred to in paragraph (b)(2) of this section, becomes worn to the extent of exposing bare conductors, the portion thus exposed shall be protected by means of rubber and friction tape or other equivalent insulation.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.760 · Fall protection

Other structural steel and precast concrete contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.