Inspection 344656095 OPENED FEB 25, 2020Closed
Great Bay Solar Ii 29900 Charles Layfield Road, Westover, MD 21871 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
Incident on Feb 23, 2020: Steel beam falls while being guided, fractures employee's fo
At approximately 3:00 p.m. on February 23, 2020, an employee, working for a contracting company erecting steel at a power plant, was guiding an 18-foot I-beam that was elevated 5 feet and attached by a magnet to the hoisting mechanism of a dedicated pile driver. When the I-beam was being hoisted, the bolt attached to the U-bolt holding the strap/magnet to the hoisting mechanism became disengaged causing the strap/magnet to disconnect from the hoisting mechanism and the I-beam fell to the ground striking the employee's foot. The employee wore safety boots without a metatarsal guard, causing fractures to the right foot in several places. The employee was treated without hospitalization.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.95(a) · Criteria for personal protective equipment |
Serious | $3,550 | $3,550 | May 21, 2020 | Final |