OSHA SearchOSHA records by employer

HDW Construction & Drilling, LLC: OSHA inspections and violations

El Paso, Texas · Water and Sewer Line and Related Structures Construction · NAICS 237110

2inspections
8citation items
$23,476current penalties
Oct 16, 2024last inspection

OSHA has inspected HDW Construction & Drilling, LLC 2 times in Texas since 2017.

The latest one began on Oct 16, 2024 as a planned inspection, in San Antonio.

Those inspections ended with 8 citation items: 1 serious and 7 other-than-serious.

Penalties were first proposed at $39,126 and now stand at $23,476, 40% lower after settlements or reviews.

Permit-required confined space program comes up most often in these citations: 2 items under 1926.1204.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and HDW Construction & Drilling, LLC averages $11,738 (2 cited inspections).

HDW Construction & Drilling, LLC: OSHA citation items per year, 2017 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

401employers cited

12 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch HDW Construction & Drilling, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347823429 OPENED OCT 16, 2024Closed

Planned · Partial · Safety · 89 employees at the site · Closed Apr 9, 2025

Riverside & Vfw Blvd, San Antonio, TX 78210 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$4,965$2,979Feb 27, 2025Final
Citation 1, item 2
29 CFR 1926.21(b)(6)(i) · Construction safety training
Other-than-serious$4,965$2,979Feb 27, 2025Final
Citation 1, item 3
29 CFR 1926.350(a)(9) · Gas welding and cutting
Other-than-serious$6,620$3,972Feb 27, 2025Final
Citation 1, item 4
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$6,620$3,972Feb 27, 2025Final
Citation 1, item 5
29 CFR 1926.652(c)(2)(iii) · Trench protection
Other-than-serious$6,620$3,972Feb 27, 2025Final
Citation 1, item 6a
29 CFR 1926.1204(e)(1) · Permit-required confined space program
Other-than-serious$6,620$3,972Feb 27, 2025Final
Citation 1, item 6b
29 CFR 1926.1204(e)(2) · Permit-required confined space program
Other-than-serious$0$0Feb 27, 2025Final

Inspection 342605706 OPENED AUG 31, 2017Closed

Planned · Partial · Safety · 5 employees at the site · Closed Oct 25, 2017

Monticello And N Mesa, El Paso, TX 79912 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$2,716$1,630Oct 10, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1926.1204 · Permit-required confined space program

29 CFR 1926.1204(e)(1)

(1) Test conditions in the permit space to determine if acceptable entry conditions exist before changes to the space's natural ventilation are made, and before entry is authorized to begin, except that, if an employer demonstrates that isolation of the space is infeasible because the space is large or is part of a continuous system (such as a sewer), the employer must:

29 CFR 1926.1204(e)(2)

(2) Continuously monitor atmospheric hazards unless the employer can demonstrate that the equipment for continuously monitoring a hazard is not commercially available or that periodic monitoring is of sufficient frequency to ensure that the atmospheric hazard is being controlled at safe levels. If continuous monitoring is not used, periodic monitoring is required with sufficient frequency to ensure that acceptable entry conditions are being maintained during the course of entry operations;

29 CFR 1926.21 · Construction safety training

29 CFR 1926.350 · Gas welding and cutting

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.