Inspection 346186893 OPENED AUG 31, 2022Closed
15 Dana Rd., Valhalla, NY 10595 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Healy Electric Contracting 6 times in New York since 1992.
The latest one began on Aug 31, 2022 after a complaint, in Valhalla.
Those inspections ended with 8 citation items: 7 serious and 1 other-than-serious.
Penalties were first proposed at $17,339 and now stand at $8,303, 52% lower after settlements or reviews.
Ground-fault protection on job sites comes up most often in these citations: 3 items under 1926.404.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Healy Electric Contracting averages $2,800 (1 cited inspection).
New York · latest 90 days of OSHA records
353employers cited
8 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Healy Electric Contracting and get notified the morning OSHA posts a new citation for it.
Watch this company15 Dana Rd., Valhalla, NY 10595 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
15 Dana Rd., Valhalla, NY 10595 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.405(g)(2)(iii) · Job-site wiring |
Other-than-serious | $9,324 | $2,800 | Sep 22, 2022 | Final |
3026 East Main Street, Yortlandt Manor, NY 10567 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.451(b)(2) · Scaffolds, general requirements |
Serious | $5,390 | $3,234 | Jan 30, 2012 | Closed |
| Citation 1, item 1b 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $0 | $0 | Jan 30, 2012 | Closed |
2 Brewster Road, Scarsdale, NY 10583 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $525 | $410 | Feb 17, 2009 | Closed |
| Citation 1, item 2 29 CFR 1926.1052(c)(12) · Stairways in construction |
Serious | $300 | $210 | Feb 17, 2009 | Closed |
Child Care Center, West. Co. Community College, Valhalla, NY 10595 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Serious | $750 | $600 | Jan 10, 1996 | Closed |
One North Broadway, White Plains, NY 10651 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.404(a)(2) · Ground-fault protection on job sites |
Serious | $1,050 | $1,050 | May 12, 1992 | Closed |
| Citation 1, item 1b 29 CFR 1926.404(f)(6) · Ground-fault protection on job sites |
Serious | $0 | $0 | May 12, 1992 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1052(c)(12)
(12) Unprotected sides and edges of stairway landings shall be provided with guardrail systems. Guardrail system criteria are contained in subpart M of this part.
29 CFR 1926.404(a)(2)
(2) Polarity of connections. No grounded conductor shall be attached to any terminal or lead so as to reverse designated polarity.
29 CFR 1926.404(b)(1)(i)
(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.