OSHA SearchOSHA records by employer

Hebert Masonry: OSHA inspections and violations

Baton Rouge, Louisiana · Masonry Contractors · NAICS 238140

2inspections
7citation items
$5,006current penalties
Oct 19, 2017last inspection

Since 2008, OSHA inspectors have visited Hebert Masonry in Louisiana 2 times.

The most recent inspection opened on Oct 19, 2017 as a planned inspection, in Baton Rouge.

In all, OSHA issued 7 citation items: 6 serious and 1 other-than-serious.

The proposed penalties came to $15,586; today they stand at $5,006, 68% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. Hebert Masonry averages $4,781 across 1 cited inspection.

Hebert Masonry: OSHA citation items per year, 2008 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Hebert Masonry again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342716545 OPENED OCT 19, 2017Closed

Planned · Partial · Safety · 4 employees at the site · Closed Sep 18, 2019

2106 Elwood Ct, Baton Rouge, LA 70809 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Other-than-serious$3,259$0Dec 19, 2017Final
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,803$1,521Dec 19, 2017Final
Citation 1, item 3
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,630$652Dec 19, 2017Final
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,803$1,521Dec 19, 2017Final
Citation 1, item 5
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,716$1,086Dec 19, 2017Final

Inspection 311521116 OPENED MAR 11, 2008Closed

Planned · Complete · Safety · 5 employees at the site · Closed Apr 29, 2008

10200 Daradele Ave, Baton Rouge, LA 70810 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$375$225Mar 13, 2008Closed
Citation 1, item 1b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Mar 13, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.501 · Fall protection in construction

Other masonry contractors employers in Louisiana

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.