OSHA SearchOSHA records by employer

Hector Hernandez: OSHA inspections and violations

Raleigh, North Carolina · Masonry Contractors · NAICS 238140

2inspections
12citation items
$3,300current penalties
May 3, 2017last inspection

Hector Hernandez has 2 OSHA inspections on record in North Carolina, the first in 2016.

OSHA's last visit started on May 3, 2017 as a planned inspection, in Rural Hall.

Across those inspections OSHA issued 12 citation items: 10 serious and 2 other-than-serious.

OSHA proposed $3,300 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Hector Hernandez averages $1,650 over 2 cited inspections in that time.

Hector Hernandez: OSHA citation items per year, 2016 to 2017
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

237employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Hector Hernandez and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342300548 OPENED MAY 3, 2017Closed

Planned · Complete · Safety · 5 employees at the site · Closed May 17, 2022

6455 Bentbrush St Lot 165, Rural Hall, NC 27045 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,500$1,500May 19, 2017Final
Citation 1, item 2b
29 CFR 1926.503(b)(1) · Fall protection training in construction
Serious$0$0May 19, 2017Final
Citation 2, item 1
29 CFR 1926.404(b)(1)(iii)(c) · Ground-fault protection on job sites
Other-than-serious$0$0May 19, 2017Final
Citation 2, item 2
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0May 19, 2017Final

Inspection 341997955 OPENED DEC 20, 2016Closed

Planned · Complete · Safety · 2 employees at the site · Closed Apr 26, 2018

314 Cabarrus St, Raleigh, NC 27699 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$900$900Feb 2, 2017Final
Citation 1, item 1b
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$0$0Feb 2, 2017Final
Citation 1, item 1c
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Feb 2, 2017Final
Citation 1, item 1d
29 CFR 1926.451(g)(4)(iv) · Scaffolds, general requirements
Serious$0$0Feb 2, 2017Final
Citation 1, item 1e
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Feb 2, 2017Final
Citation 1, item 1f
29 CFR 1926.452(a)(4) · Rules for each type of scaffold
Serious$0$0Feb 2, 2017Final
Citation 1, item 1g
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Feb 2, 2017Final
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$900$900Feb 2, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(iii)(c)

(C) Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, shall be visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective shall not be used until repaired.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other masonry contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.