OSHA SearchOSHA records by employer

Hector Martinez Lerma: OSHA inspections and violations

Grand Prairie, Texas · Masonry Contractors · NAICS 238140

1inspections
5citation items
$5,200current penalties
Apr 17, 2015last inspection

Hector Martinez Lerma has one OSHA inspection on record in Texas.

OSHA opened it on Apr 17, 2015 as a planned inspection, in Grand Prairie.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $5,200 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Hector Martinez Lerma averages $5,200 over 1 cited inspection in that time.

Hector Martinez Lerma: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Hector Martinez Lerma and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340570688 OPENED APR 17, 2015Closed

Planned · Partial · Safety · 4 employees at the site · Closed Apr 23, 2018

5010 Hwy 360, Grand Prairie, TX 75050 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,000$2,000May 14, 2015Final
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0May 14, 2015Final
Citation 1, item 2a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,000$2,000May 14, 2015Final
Citation 1, item 2b
29 CFR 1926.452(b)(2) · Rules for each type of scaffold
Serious$0$0May 14, 2015Final
Citation 1, item 3
29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction
Serious$1,200$1,200May 14, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.602 · Earthmovers and forklifts in construction

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.