Inspection 348743584 OPENED FEB 11, 2026Closed
Teton 56-2-35-23-g , 14h (h&p 396) 4.9 Miles Se From Orla, Orla, TX 79770 · Drilling Oil and Gas Wells · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Helmerich and Payne, Inc. 19 times in Texas since 2011.
The latest one began on Feb 11, 2026 as a planned inspection, in Orla.
Those inspections ended with 9 citation items: 3 serious and 6 other-than-serious.
Penalties were first proposed at $69,652 and now stand at $40,005, 43% lower after settlements or reviews.
Electrical wiring methods comes up most often in these citations: 3 items under 1910.305.
How that compares: the median penalty per cited inspection for mining and oil and gas employers since 2015 is $2,886, and Helmerich and Payne, Inc. averages $1,618 (3 cited inspections).
Helmerich and Payne, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 8 severe injuries to OSHA since 2015.
Texas · latest 90 days of OSHA records
399employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch Helmerich and Payne, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this companyOSHA records show Helmerich and Payne, Inc. at 15 sites in 3 states. Together they've had 23 inspections and $60,309 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 15 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
See plansTeton 56-2-35-23-g , 14h (h&p 396) 4.9 Miles Se From Orla, Orla, TX 79770 · Drilling Oil and Gas Wells · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Big Baby B, 411h 5.4 Miles Nw From Pecos, Pecos, TX 79772 · Drilling Oil and Gas Wells · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.305(j)(1)(i) · Electrical wiring methods |
Other-than-serious | $1,328 | $797 | Aug 7, 2026 | Final |
Valkyrie State 57-2-40 Unit 13ha Lat 31.9700646400; Long 103.771383762, Pecos, TX 79772 · Drilling Oil and Gas Wells · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3093 Cr 123, De Berry, TX 75639 · Drilling Oil and Gas Wells · OSHA's record · Phone and website on Google Maps
Incident on Jan 3, 2022: Employee lacerates liver when caught between st-80 and mast
At 6:45 a.m. on January 3, 2022, an employee made a connection on the rig floor and began stowing an ST-80. The employee was injured when he was caught between the ST-80 and an oil rig mast. The employee was hospitalized for treatment of a lacerated liver.
No citations from this inspection.
Tinian-prewit 24-14 Unit Well 321 H (rig # 510) 9.6 Miles Sw Direction From Pecos, Pecos, TX 79772 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Powered Donut State C Well # C 13h (rig 296) 7.9 Miles Nw Direction From Pecos, Pecos, TX 79772 · Drilling Oil and Gas Wells · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Lease Vintage D Well No.26 H 6.5 Miles Nw Of Pecos, Pecos, TX 79772 · Drilling Oil and Gas Wells · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.305(a)(2)(xi) · Electrical wiring methods |
Other-than-serious | $931 | $559 | Mar 23, 2021 | Final |
Lease: Pecan State Unit, Well: 4108ch 7.6 Miles Ne Direction From Coyanosa, Fort Stockton, TX 79735 · Drilling Oil and Gas Wells · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Rig #381, 22.1 Miles Northwest Of Pecos, Tx., Pecos, TX 79772 · Drilling Oil and Gas Wells · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.24(f) · Fixed industrial stairs |
Other-than-serious | $4,543 | $3,500 | Sep 16, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.303(b)(8)(iii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Sep 16, 2016 | Final |
Wildcat-elsinore 70, Rig #639 22 Mi. S. Of Ft. Stockton, Fort Stockton, TX 79735 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
N 30.9070699 W 94.1471101, Jasper, TX 75951 · Drilling Oil and Gas Wells · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Lat: 28 43'19.196n Long: 098 13'30.900w, Peggy, TX 78062 · Oil and Gas Extraction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
N 28.430.151 W99.713.902 2 Miles South Of Asherton Texas 78827, Asherton, TX 78827 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Deadwood (fusselman) Gilbreath M/h Well # 3, Garden City, TX 79739 · Drilling Oil and Gas Wells · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
N 30 46.785 W 94 35.745, Livingston, TX 77351 · Drilling Oil and Gas Wells · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(2) · Machine guarding |
Serious | $7,000 | $4,200 | Apr 29, 2013 | Final |
H&p Inc. Rig #347, Collie (delaware) Field, Crouch Lease, Well #3,2.1 Miles Ne From Pecos, Tx, Pecos, TX 79772 · Drilling Oil and Gas Wells · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.304(g)(5) · Grounding and circuit protection |
Other-than-serious | $6,600 | $3,300 | May 1, 2013 | Final |
Beckham Lease, Collie Field, Well#2, Flex Rig#347, Pecos, TX 79772 · Drilling Oil and Gas Wells · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $38,500 | $20,000 | Jan 24, 2012 | Closed |
North Penwell Unit 269, Odessa, TX 79711 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $7,000 | $5,000 | Sep 26, 2011 | Closed |
Falkono:1rach Ltd, Rig #303, Midland, TX 79705 · Drilling Oil and Gas Wells · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 2 29 CFR 1910.304(g)(5) · Grounding and circuit protection |
Other-than-serious | $3,750 | $2,650 | Sep 30, 2011 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Odessa site logged 66 recordable injuries or illnesses among about 2,818 workers: 1.8 per 100 full-time workers, against a median of 0.2 for its industry. Those cases cost 803 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| H&P U.S. Land - West Odessa · 2025 | 2,818 | 66 | 12 | 1.8 | 0.2 |
Included with any plan: 3 more yearly logs from these sites, back to 2022, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansEmployers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 8 reports on file, the 6 most recent shown.
Feb 12, 2024, Odessa: Hospitalization, amputation · amputations, avulsions, enucleations unspecified · finger or thumb tip(s), nail(s)
An employee was operating a winch when his left hand got caught under a cable, resulting in an amputation of the ring fingertip.
Jan 2, 2023, Orla: Hospitalization, amputation · amputations · fingertip(s)
A crew was installing skid rails. The injured employee was checking the alignment of two sections of skid rails when the pieces moved and his right middle and ring fingers were caught in the pin hole connection of the two sections. Both fingertips were amputated.
Jan 3, 2022, De Berry: Hospitalization · internal injuries to organs and blood vessels of the trunk · abdomen, except internal location of diseases or disorders
An employee was caught between pieces of drilling equipment (ST-80 and mast leg) while making a connection on the rig floor, resulting in a lacerated liver.
May 25, 2021, Midland: Hospitalization · traumatic injuries and disorders, unspecified · nonclassifiable
An employee fell about 20 feet from an aerial lift while pulling cables.
Mar 7, 2019, Midland: Hospitalization · crushing injuries · finger(s), fingernail(s), unspecified
Employees were attempting to dislodge a flow line from a hand rail. The rail came loose and fell on the employee's thumb, crushing it.
Aug 27, 2018, Midland: Amputation · amputations · fingertip(s)
An employee was collecting samples and his left hand entered a peach when the winch moved, resulting in a left index fingertip amputation.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.151(c)
(c) Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.
29 CFR 1910.212(a)(2)
(2) General requirements for machine guards. Guards shall be affixed to the machine where possible and secured elsewhere if for any reason attachment to the machine is not possible. The guard shall be such that it does not offer an accident hazard in itself.
29 CFR 1910.303(b)(8)(iii)
(iii) Electric equipment provided with ventilating openings shall be installed so that walls or other obstructions do not prevent the free circulation of air through the equipment.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.