OSHA SearchOSHA records by employer

Henkel US Operations Corporation: OSHA inspections and violations

Warrensville Heights, Ohio · Adhesive Manufacturing · NAICS 325520

2inspections
2citation items
$14,956current penalties
Jan 23, 2025last inspection

Henkel US Operations Corporation has 2 OSHA inspections on record in Ohio, the first in 2019.

OSHA's last visit started on Jan 23, 2025 after a complaint, in Warrensville Heights.

Across those inspections OSHA issued 2 citation items: 2 other-than-serious.

OSHA proposed $22,717 in penalties. After settlements and reviews the total is $14,956, down 34%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Henkel US Operations Corporation averages $7,478 over 2 cited inspections in that time.

Henkel US Operations Corporation also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Henkel US Operations Corporation: OSHA citation items per year, 2019 to 2025
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

257employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Henkel US Operations Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Henkel US Operations Corporation at 2 sites in 2 states. Together they've had 3 inspections and $15,456 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 2 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 347995599 OPENED JAN 23, 2025Closed

Complaint · Partial · Health · 160 employees at the site · Closed Nov 24, 2025

18371 Cranwood Pkwy, Warrensville Heights, OH 44128 · Adhesive Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(m)(4) · Respiratory protection
Other-than-serious$9,457$5,674Apr 22, 2025Final

Inspection 344462619 OPENED NOV 20, 2019Closed

Referral · Partial · Safety · 53,000 employees at the site · Closed Feb 13, 2020

18371 Cranwood Pkwy, Warrensville Heights, OH 44128 · Adhesive Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Nov 14, 2019: Employee fractures finger while removing pump from mixer

At 1:00 p.m. on November 14, 2019, an employee was working for a chemical firm that manufactured adhesives. He was an operations and systems researcher and analyst. Among his duties, he operated a Molteni chemical mixer. It was the facility's mixer number 3, with serial number W602-SIL01-A001. He was performing service and maintenance on the mixer. He was cleaning out the mixer and removing the mixer's drum pump. Workers at the facility used the drum pump for the accurate blending of chemical material. The employee was removing the drum pump by disconnecting the pump's Victaulic fitting, when the pump suddenly dropped. The small finger on the employee's left hand was caught between the pump stand and the fitting. The finger was fractured. The employee was hospitalized. Surgery was required to repair the damaged finger. The facility did not have a specific energy control procedure to account for the weight of the pump when it was removed from the mixer. The workers actuated a Victaulic fitting to release the pump from the mixer, but the pump's weight was not controlled. The company did have specific procedures for the drum pump and drum change, general mixing procedures, instructions for the mixer, and specific lockout procedures for the mixer. When the employer introduced the drum pump and pump stand into the production operation, the procedures were not updated to control the hazardous energy of the drum pump's weight when it was removed. The company had introduced the drum pump to aid in production. It reviewed the energy control procedures on an annual basis. The chemical mixer employees had expressed concern over the drum pump and pump stand prior to the incident. The procedures had not been updated to include energy isolation of the drum pump.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Other-than-serious$13,260$9,282Jan 6, 2020Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Warrensville Heights site logged 8 recordable injuries or illnesses among about 158 workers: 4.8 per 100 full-time workers, against a median of 2.0 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Henkel US Operations Corporation - Cleveland
Warrensville Heights · 2024
158 804.82.0

Included with any plan: 1 more yearly log from these sites, back to 2023, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Nov 14, 2019, Warrensville Heights: Hospitalization · fractures · finger(s), fingernail(s), unspecified

An employee was connecting a pipe fitting when the pressure of the pump dropped and his pinky finger was caught between the fitting and pump stand, resulting in a severe fracture that required surgery.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(m)(4)

(4) Written materials required to be retained under this paragraph shall be made available upon request to affected employees and to the Assistant Secretary or designee for examination and copying.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(ii)

(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:

Other adhesive manufacturing employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.