OSHA SearchOSHA records by employer

Henry Stone Mason, Inc.: OSHA inspections and violations

Watertown, New York · Masonry Contractors · NAICS 238140

1inspections
6citation items
$4,000current penalties
Jul 29, 2015last inspection

OSHA has inspected Henry Stone Mason, Inc. once in New York.

The inspection began on Jul 29, 2015 as a planned inspection, in Watertown.

That inspection ended with 6 citation items: 6 serious.

Penalties were first proposed at $4,000 and still stand at $4,000.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Henry Stone Mason, Inc. averages $4,000 (1 cited inspection).

Henry Stone Mason, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Henry Stone Mason, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340810530 OPENED JUL 29, 2015Closed

Planned · Complete · Safety · 4 employees at the site · Closed Mar 15, 2019

Longhorn Steakhouse, 20990 Salmon Run Mall Loop, Watertown, NY 13601 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,000$2,000Sep 15, 2015Final
Citation 1, item 1b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Sep 15, 2015Final
Citation 1, item 1c
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$0$0Sep 15, 2015Final
Citation 1, item 1d
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Sep 15, 2015Final
Citation 1, item 2a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$2,000$2,000Sep 15, 2015Final
Citation 1, item 2b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Sep 15, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.