OSHA SearchOSHA records by employer

Herman-Stewart Construction and Development, Inc.: OSHA inspections and violations

Hanover, Maryland · Commercial and Institutional Building Construction · NAICS 236220

15inspections
20citation items
$9,344current penalties
May 30, 2018last inspection

OSHA has inspected Herman-Stewart Construction and Development, Inc. 15 times in Maryland since 1996.

The latest one began on May 30, 2018 as a planned inspection, in Gambrills.

Those inspections ended with 20 citation items: 14 serious, 1 repeat and 5 other-than-serious.

Penalties were first proposed at $16,960 and now stand at $9,344, 45% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 6 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Herman-Stewart Construction and Development, Inc. averages $1,574 (1 cited inspection).

Herman-Stewart Construction and Development, Inc.: OSHA citation items per year, 1996 to 2018
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

182employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Herman-Stewart Construction and Development, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343199204 OPENED MAY 30, 2018Closed

Planned · Complete · Safety · 1 employee at the site · Closed Aug 17, 2018

329 Gambrills Road, Gambrills, MD 21054 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$787$787Jul 31, 2018Final
Citation 1, item 2
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Serious$787$787Jul 31, 2018Final

Inspection 342311321 OPENED MAY 9, 2017Closed

Unprogrammed other · Complete · Safety · 30 employees at the site · Closed May 10, 2017

2223 York Road, Lutherville Timonium, MD 21093 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316970680 OPENED SEP 17, 2013Open

Planned · Complete · Safety · 1 employee at the site · Open

5616 Spectrum Drive, Frederick, MD 21703 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 315784140 OPENED SEP 14, 2011Closed

Planned · Complete · Safety · 3 employees at the site · Closed Sep 14, 2011

5050 Westview Drive, Frederick, MD 21703 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315061697 OPENED DEC 7, 2010Open

Planned · Complete · Safety · 4 employees at the site · Open

4550 Forbes Boulevard, Lanham, MD 20706 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.201(a) · Signaling
Serious$750$375Jan 3, 2011Open

Inspection 309762797 OPENED MAR 1, 2006Closed

Planned · Complete · Safety · 2 employees at the site · Closed May 4, 2006

441 Outlet Center Drive, Queenstown, MD 21658 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$1,925$960Apr 3, 2006Closed
Citation 2, item 1
29 CFR 1926.760(a)(1) · Fall protection
Serious$1,925$960Apr 3, 2006Closed
Citation 3, item 1 Other-than-serious$0$0Apr 3, 2006Closed

Inspection 305449886 OPENED FEB 12, 2003Closed

Planned · Complete · Safety · 2 employees at the site · Closed May 14, 2003

7027 Arundel Mills Boulevard, Hanover, MD 21076 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,200$600Mar 17, 2003Closed

Inspection 305586497 OPENED FEB 11, 2003Closed

Planned · Complete · Safety · 3 employees at the site · Closed Apr 15, 2003

8320 Benson Drive, Columbia, MD 21045 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$525$525Mar 24, 2003Closed
Citation 1, item 1b Serious$0$0Mar 24, 2003Closed
7 older inspections

Inspection 306072075 OPENED JAN 21, 2003Closed

Planned · Complete · Safety · 2 employees at the site · Closed Apr 4, 2003

4980 Mercantile Road, White Marsh, MD 21162 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Feb 19, 2003Closed

Inspection 305295180 OPENED APR 11, 2002Closed

Unprogrammed other · Complete · Safety · 2 employees at the site · Closed Apr 12, 2002

7027 Arundel Mills Boulevard, Hanover, MD 21076 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 303894364 OPENED AUG 10, 2000Closed

Planned · Complete · Safety · 2 employees at the site · Closed Oct 24, 2000

Springhill Stes By Marriott, 899 Elkridge Landing, Linthicum Heights, MD 21090 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$1,575$575Sep 19, 2000Closed

Inspection 303592604 OPENED JUL 11, 2000Closed

Planned · Complete · Safety · 1 employee at the site · Closed Sep 14, 2000

8168 Elliot Road, Easton, MD 21601 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$562$450Aug 15, 2000Closed
Citation 2, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$675$450Aug 15, 2000Closed
Citation 3, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$787$450Aug 15, 2000Closed

Inspection 302884416 OPENED SEP 7, 1999Closed

Planned · Complete · Safety · 1 employee at the site · Closed Nov 18, 1999

2430 Solomons Island Road, Route 2, Annapolis, MD 21401 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$1,000$1,000Oct 12, 1999Closed
Citation 2, item 1
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$200$200Oct 12, 1999Closed
Citation 3, item 1 Other-than-serious$0$0Oct 12, 1999Closed

Inspection 119565430 OPENED MAY 5, 1997Closed

Planned · Complete · Safety · 2 employees at the site · Closed Sep 26, 1997

1150 Winterson Lane, Linthicum, MD 21090 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(i) · Fire protection
Other-than-serious$900$225Jul 17, 1997Closed
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Other-than-serious$1,575$450Jul 17, 1997Closed
Citation 3, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$787$550Jul 17, 1997Closed

Inspection 127374759 OPENED AUG 14, 1996Closed

Planned · Complete · Safety · 1 employee at the site · Closed Oct 7, 1996

4500 Mitchelleville Road, Bowie, MD 20715 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 0912.2303

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(i)

(i) At least one handrail; and

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.201 · Signaling

29 CFR 1926.201(a)

(a) Flaggers. Signaling by flaggers and the use of flaggers, including warning garments worn by flaggers, shall conform to Part 6 of the MUTCD (incorporated by reference, see § 1926.6).

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.652 · Trench protection

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.760 · Fall protection

Other commercial and institutional building construction employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.