OSHA SearchOSHA records by employer

Herrera Concrete LLC: OSHA inspections and violations

Alpharetta, Georgia · Poured Concrete Foundation and Structure Contractors · NAICS 238110

1inspections
3citation items
$4,768current penalties
May 15, 2025last inspection

OSHA has inspected Herrera Concrete LLC once in Georgia.

The inspection began on May 15, 2025 as a planned inspection, in Alpharetta; the case is still open.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $7,946 and now stand at $4,768, 40% lower after settlements or reviews.

Excavations comes up most often in these citations: 2 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Herrera Concrete LLC averages $4,768 (1 cited inspection).

Herrera Concrete LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

145employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Herrera Concrete LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348250416 OPENED MAY 15, 2025Open

Planned · Partial · Safety · 2 employees at the site · Open

126 Lily Garden Place, Alpharetta, GA 30009 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$2,838$1,703Nov 13, 2025Final
Citation 1, item 2
29 CFR 1926.651(j)(2) · Excavations
Serious$2,270$1,362Nov 13, 2025Final
Citation 1, item 3
29 CFR 1926.652(a)(1) · Trench protection
Serious$2,838$1,703Nov 13, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when: