OSHA SearchOSHA records by employer

Hewitt Steel Inc: OSHA inspections and violations

Lake Worth, Florida · Structural Steel and Precast Concrete Contractors · NAICS 238120

3inspections
4citation items
$7,829current penalties
Jun 30, 2020last inspection

Hewitt Steel Inc has 3 OSHA inspections on record in Florida, the first in 2010.

OSHA's last visit started on Jun 30, 2020 on a referral, in Madeira Beach.

Across those inspections OSHA issued 4 citation items: 4 serious.

OSHA proposed $13,648 in penalties. After settlements and reviews the total is $7,829, down 43%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Hewitt Steel Inc averages $2,429 over 1 cited inspection in that time.

It reported 1 severe injury to OSHA since 2015.

Hewitt Steel Inc: OSHA citation items per year, 2010 to 2020
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

319employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Hewitt Steel Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344822994 OPENED JUN 30, 2020Closed

Referral · Partial · Safety · 5 employees at the site · Closed Nov 5, 2020

15305 1st Street East, Madeira Beach, FL 33708 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jun 25, 2020: Employee falls to ground and sustains multiple fractures

At 10:00 a.m. on June 25, 2020, Employee #1 was working for structural contractor. Employee #1 was accessing a work platform when he fell 22 feet. Employee #1 suffered fractures to the head, sternum, pelvis, leg, ribs and discs. Employee #1 was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$4,048$2,429Sep 29, 2020Final

Inspection 315968578 OPENED AUG 8, 2011Open

Planned · Partial · Safety · 4 employees at the site · Open

26645 State Route 54, Wesley Chapel, FL 33545 · Tax Preparation Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$2,400$1,200Aug 23, 2011Open
Citation 2, item 1
29 CFR 1926.451(g)(1)(v) · Scaffolds, general requirements
Serious$4,800$2,400Aug 23, 2011Open

Inspection 314265778 OPENED OCT 8, 2010Closed

Planned · Partial · Health · 3 employees at the site · Closed Nov 24, 2010

7001 Charleston Shores Blvd, Lake Worth, FL 33467 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,400$1,800Nov 23, 2010Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jun 25, 2020, Madeira Beach: Hospitalization · fractures · multiple body parts, n.e.c.

An employee was going across a working platform when he fell to the ground 30 feet below. He suffered multiple fractures to his head, sternum, and pelvis; a broken left arm; and a broken back with three disc fractures.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(1)(v)

(v) Each employee on a walkway located within a scaffold shall be protected by a guardrail system (with minimum 200 pound toprail capacity) installed within 9 1/2 inches (24.1 cm) of and along at least one side of the walkway.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other structural steel and precast concrete contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.