OSHA SearchOSHA records by employer

HGM Industries, Inc: OSHA inspections and violations

Marblehead, Massachusetts · Roofing Contractors · NAICS 238160

5inspections
12citation items
$30,410current penalties
Feb 27, 2017last inspection

OSHA has inspected HGM Industries, Inc 5 times in Massachusetts since 2004.

The latest one began on Feb 27, 2017 after a complaint, in Marblehead.

Those inspections ended with 12 citation items: 10 serious and 2 repeat.

Penalties were first proposed at $46,203 and now stand at $30,410, 34% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and HGM Industries, Inc averages $14,000 (1 cited inspection).

HGM Industries, Inc: OSHA citation items per year, 2004 to 2017
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

260employers cited

54 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch HGM Industries, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342133980 OPENED FEB 27, 2017Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Aug 7, 2023

14 Casino Road, Marblehead, MA 01945 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$19,013$14,000Mar 13, 2017Final

Inspection 339767279 OPENED MAY 14, 2014Closed

Complaint · Partial · Safety · 3 employees at the site · Closed May 11, 2017

1 Front Street, Marblehead, MA 01945 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$15,400$6,160Jun 13, 2014Final

Inspection 339415101 OPENED SEP 16, 2013Closed

Complaint · Complete · Safety · 6 employees at the site · Closed May 11, 2017

20 Walker Road, Swampscott, MA 01907 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements
Serious$2,520$1,750Nov 6, 2013Final
Citation 1, item 1b
29 CFR 1926.452(k)(5) · Rules for each type of scaffold
Serious$0$0Nov 6, 2013Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,520$1,750Nov 6, 2013Final

Inspection 315871855 OPENED SEP 29, 2011Closed

Complaint · No inspection · Safety · Closed Sep 30, 2011

Atlantic And Ocean Avenue, Marblehead, MA 01945 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306102690 OPENED SEP 1, 2004Closed

Unprogrammed other · Complete · Safety · 10 employees at the site · Closed Oct 24, 2008

1 Johnson Road, North Andover, MA 01845 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,500$1,500Dec 2, 2004Closed
Citation 1, item 2a
29 CFR 1926.452(k)(1) · Rules for each type of scaffold
Serious$1,500$1,500Dec 2, 2004Closed
Citation 1, item 2b
29 CFR 1926.451(f)(15) · Scaffolds, general requirements
Serious$0$0Dec 2, 2004Closed
Citation 1, item 2c
29 CFR 1926.452(k)(5) · Rules for each type of scaffold
Serious$0$0Dec 2, 2004Closed
Citation 1, item 3
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$750$750Dec 2, 2004Closed
Citation 1, item 4
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$1,500$1,500Dec 2, 2004Closed
Citation 1, item 5
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,500$1,500Dec 2, 2004Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(15)

(15) Ladders shall not be used on scaffolds to increase the working level height of employees, except on large area scaffolds where employers have satisfied the following criteria:

29 CFR 1926.451(f)(6)

(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.