OSHA SearchOSHA records by employer

High Desert Hospice: OSHA inspections and violations

Albuquerque, New Mexico · Nursing Care Facilities (Skilled Nursing Facilities) · NAICS 623110

2inspections
4citation items
$7,000current penalties
Mar 3, 2025last inspection

OSHA has inspected High Desert Hospice 2 times in New Mexico since 2023.

The latest one began on Mar 3, 2025 to follow up on an earlier case, in Albuquerque; the case is still open.

Those inspections ended with 4 citation items: 1 serious and 3 other-than-serious.

Penalties were first proposed at $7,000 and still stand at $7,000.

How that compares: the median penalty per cited inspection for health care employers since 2015 is $1,050, and High Desert Hospice averages $7,000 (1 cited inspection).

High Desert Hospice: OSHA citation items per year, 2023 to 2025
Citation items per year, by inspection date.

New Mexico · latest 90 days of OSHA records

31employers cited

Get notified the morning OSHA posts each new citation in New Mexico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Mexico

Checking a subcontractor, a client or your own company? Watch High Desert Hospice and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348076472 OPENED MAR 3, 2025Open

Follow-up · Partial · Health · 70 employees at the site · Open

8661 San Pedro Drive Northeast, Albuquerque, NM 87113 · Nursing Care Facilities (Skilled Nursing Facilities) · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 346993173 OPENED SEP 25, 2023Open

Planned · Complete · Health · 70 employees at the site · Open

8661 San Pedro Drive Northeast, Albuquerque, NM 87113 · Nursing Care Facilities (Skilled Nursing Facilities) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$7,000$7,000Mar 22, 2024Final
Citation 2, item 1
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$0$0Mar 22, 2024Final
Citation 2, item 2
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Mar 22, 2024Final
Citation 2, item 3
29 CFR 1910.303(e)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Mar 22, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(2)

(2) Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(e)(1)(ii)

(ii) Other markings giving voltage, current, wattage, or other ratings as necessary.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1910.37 · Exit routes

Other nursing care facilities (skilled nursing facilities) employers in New Mexico

Alert subscribers get notified of each newly cited employer in New Mexico the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.