OSHA SearchOSHA records by employer

High West Energy Inc: OSHA inspections and violations

Pine Bluffs, Wyoming · Electric Power Distribution · NAICS 221122

1inspections
2citation items
$2,975current penalties
Mar 6, 2017last inspection

OSHA has inspected High West Energy Inc once in Wyoming.

The inspection began on Mar 6, 2017 on a referral, in Pine Bluffs.

That inspection ended with 2 citation items: 1 serious and 1 other-than-serious.

Penalties were first proposed at $2,975 and still stand at $2,975.

How that compares: the median penalty per cited inspection for utility employers since 2015 is $0, and High West Energy Inc averages $2,975 (1 cited inspection).

High West Energy Inc also files yearly injury logs with OSHA, summarized below.

High West Energy Inc: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Wyoming · latest 90 days of OSHA records

31employers cited

Get notified the morning OSHA posts each new citation in Wyoming: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wyoming

Checking a subcontractor, a client or your own company? Watch High West Energy Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342152139 OPENED MAR 6, 2017Closed

Referral · Partial · Safety · 78 employees at the site · Closed May 10, 2017

6270 County Road 212, Pine Bluffs, WY 82082 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(d)(5)(i) · Lockout/tagout
Serious$2,975$2,975Apr 5, 2017Final
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Apr 5, 2017Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Pine Bluffs site logged 0 recordable injuries or illnesses among about 52 workers: 0.0 per 100 full-time workers, against a median of 1.0 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Pine Bluffs HQ
Pine Bluffs · 2025
52 000.01.0
High West Energy, Inc.
Pine Bluffs · 2021
46 336.91.0

Included with any plan: 2 more yearly logs from these sites, back to 2021, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(2)

(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(d)(5)(i)

(5) Stored energy. (i) Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy shall be relieved, disconnected, restrained, and otherwise rendered safe.

Other electric power distribution employers in Wyoming

Alert subscribers get notified of each newly cited employer in Wyoming the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.