1inspections
8citation items
$1,224current penalties
Mar 19, 2015last inspection

OSHA has inspected Highlands Ranch Collision Center, Inc. once in Colorado.

The inspection began on Mar 19, 2015 as a planned inspection, in Littleton.

That inspection ended with 8 citation items: 4 serious and 4 other-than-serious.

Penalties were first proposed at $2,040 and now stand at $1,224, 40% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 3 items under 1910.134.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Highlands Ranch Collision Center, Inc. averages $1,224 (1 cited inspection).

Highlands Ranch Collision Center, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

142employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Highlands Ranch Collision Center, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340479088 OPENED MAR 19, 2015Closed

Planned · Complete · Health · 14 employees at the site · Closed Jul 9, 2015

9509 Titan Park Circle, Littleton, CO 80125 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(d)(3)(iii)(b)(2) · Respiratory protection
Serious$1,020$612Jun 17, 2015Final
Citation 1, item 1b
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Serious$0$0Jun 17, 2015Final
Citation 1, item 1c
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$0$0Jun 17, 2015Final
Citation 1, item 2
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$1,020$612Jun 17, 2015Final
Citation 2, item 1
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Other-than-serious$0$0Jun 17, 2015Final
Citation 2, item 2
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Other-than-serious$0$0Jun 17, 2015Final
Citation 2, item 3a
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Jun 17, 2015Final
Citation 2, item 3b
29 CFR 1910.1200(f)(6)(i) · Hazard communication
Other-than-serious$0$0Jun 17, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(6)(i)

(i) The information specified under paragraphs (f)(1)(i) through (v) of this section for labels on shipped containers; or,

29 CFR 1910.1200(g)(8)

(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.305 · Electrical wiring methods

Other automotive body, paint, and interior repair and maintenance employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.