OSHA SearchOSHA records by employer

Hinojoza Construction Services Inc: OSHA inspections and violations

Ruskin, Florida · Masonry Contractors · NAICS 238140

2inspections
7citation items
$9,300current penalties
Jul 18, 2018last inspection

OSHA has inspected Hinojoza Construction Services Inc 2 times in Florida since 2018.

The latest one began on Jul 18, 2018 as a planned inspection, in Ruskin.

Those inspections ended with 7 citation items: 7 serious.

Penalties were first proposed at $17,183 and now stand at $9,300, 46% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Hinojoza Construction Services Inc averages $4,650 (2 cited inspections).

Hinojoza Construction Services Inc: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

319employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Hinojoza Construction Services Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343310769 OPENED JUL 18, 2018Closed

Planned · Partial · Safety · 4 employees at the site · Closed Nov 19, 2019

Us Hwy 41 & 19th Ave Nw, Ruskin, FL 33570 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,217$1,140Oct 25, 2018Final
Citation 1, item 2
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$2,217$1,140Oct 25, 2018Final
Citation 1, item 3
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,217$1,140Oct 25, 2018Final
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,217$1,140Oct 25, 2018Final
Citation 1, item 5
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,217$1,140Oct 25, 2018Final

Inspection 343341889 OPENED JUL 16, 2018Closed

Planned · Partial · Safety · 5 employees at the site · Closed Dec 26, 2019

Sun Trust Bank Hwy 41 S & 19th St, Ruskin, FL 33570 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$2,772$1,660Jan 15, 2019Final
Citation 1, item 2
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Serious$3,326$1,940Jan 15, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iii)

(iii) Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(1)

(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:

29 CFR 1926.453 · Aerial lifts

Other masonry contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.