OSHA SearchOSHA records by employer

Hiskett & Sons LLC: OSHA inspections and violations

Fallon, Nevada · Ready-Mix Concrete Manufacturing · NAICS 327320

5inspections
17citation items
$5,538current penalties
Feb 1, 2024last inspection

Hiskett & Sons LLC has 5 OSHA inspections on record in Nevada, the first in 1997.

OSHA's last visit started on Feb 1, 2024 as a planned inspection, in Fallon.

Across those inspections OSHA issued 17 citation items: 5 serious and 12 other-than-serious.

OSHA proposed $9,726 in penalties. After settlements and reviews the total is $5,538, down 43%.

Most often, OSHA cited 1910.134, respiratory protection (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Hiskett & Sons LLC averages $1,588 over 2 cited inspections in that time.

Hiskett & Sons LLC: OSHA citation items per year, 1997 to 2024
Citation items per year, by inspection date.

Nevada · latest 90 days of OSHA records

114employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Nevada: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Nevada

Checking a subcontractor, a client or your own company? Watch Hiskett & Sons LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347250300 OPENED FEB 1, 2024Closed

Planned · Complete · Safety · 14 employees at the site · Closed Jun 18, 2024

2120 South Allen Road, Fallon, NV 89406 · Ready-Mix Concrete Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$2,664$1,332May 24, 2024Final
Citation 2, item 1
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0May 24, 2024Final
Citation 2, item 2
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0May 24, 2024Final

Inspection 347250466 OPENED FEB 1, 2024Closed

Planned · Complete · Health · 14 employees at the site · Closed Jun 18, 2024

2120 South Allen Road, Fallon, NV 89406 · Ready-Mix Concrete Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$3,687$1,844May 24, 2024Final
Citation 2, item 1
29 CFR 1910.134(f)(2) · Respiratory protection
Other-than-serious$0$0May 24, 2024Final
Citation 2, item 2
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Other-than-serious$0$0May 24, 2024Final
Citation 2, item 3
29 CFR 1910.1200(f)(6) · Hazard communication
Other-than-serious$0$0May 24, 2024Final

Inspection 317540912 OPENED MAR 18, 2014Closed

Complaint · Complete · Safety · 13 employees at the site · Closed May 21, 2014

2120 Allen Rd., Fallon, NV 89406 · Construction Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$900$630Apr 4, 2014Closed
Citation 1, item 2
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$1,200$840Apr 4, 2014Closed
Citation 1, item 3
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$1,275$892Apr 4, 2014Closed
Citation 2, item 1
29 CFR 1910.23(a)(5) · Guarding floor and wall openings and holes
Other-than-serious$0$0Apr 4, 2014Closed
Citation 2, item 2
29 CFR 1910.23(a)(9) · Guarding floor and wall openings and holes
Other-than-serious$0$0Apr 4, 2014Closed
Citation 2, item 3
29 CFR 1910.146(c)(4) · Permit-required confined spaces
Other-than-serious$0$0Apr 4, 2014Closed
Citation 3, item 1 Other-than-serious$0$0Apr 4, 2014Closed

Inspection 301909438 OPENED SEP 18, 1997Closed

Planned · Complete · Safety · 4 employees at the site · Closed Sep 18, 1997

55 Commercial Way, Fallon, NV 89406 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301700167 OPENED APR 29, 1997Closed

Planned · Complete · Safety · 5 employees at the site · Closed Aug 5, 1997

2121 Trento Lane (smi Joists), Fallon, NV 89406 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.601(b)(2)(ii) · Motor vehicles
Other-than-serious$0$0Apr 30, 1997Closed
Citation 1, item 2
29 CFR 1926.602(a)(9)(i) · Earthmovers and forklifts in construction
Other-than-serious$0$0Apr 30, 1997Closed
Citation 1, item 3
29 CFR 1926.21(a) · Construction safety training
Other-than-serious$0$0Apr 30, 1997Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(6)

(6) Workplace labeling. Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer shall ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked with either:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1926.21 · Construction safety training

29 CFR 1926.601 · Motor vehicles

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 6180.8800

Other ready-mix concrete manufacturing employers in Nevada

Alert subscribers get notified of each newly cited employer in Nevada the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.