OSHA SearchOSHA records by employer

HM Plumbing Group LLC: OSHA inspections and violations

Rensselaer, New York · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

1inspections
2citation items
$4,703current penalties
Apr 1, 2025last inspection

HM Plumbing Group LLC has one OSHA inspection on record in New York.

OSHA opened it on Apr 1, 2025 as part of a related case, in Rensselaer, and the case has not closed yet.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $7,235 in penalties. After settlements and reviews the total is $4,703, down 35%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. HM Plumbing Group LLC averages $4,703 over 1 cited inspection in that time.

HM Plumbing Group LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch HM Plumbing Group LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348148297 OPENED APR 1, 2025Open

Unprogrammed related · Partial · Safety · 3 employees at the site · Open

20 Herrick Street, Rensselaer, NY 12144 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(xv) · Scaffolds, general requirements
Serious$3,015$1,960May 20, 2025Final
Citation 1, item 2
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$4,220$2,743May 20, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(4)(xv)

(xv) Crossbracing is acceptable in place of a midrail when the crossing point of two braces is between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform or as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform. The end points at each upright shall be no more than 48 inches (1.3 m) apart.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

Other plumbing, heating, and air-conditioning contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.